D. Firescreen
A rescreen is always provided to control sparks. It must be
closed whenever the replace is in use. Glass doors or re-
screens must not be used to hold burning material inside the
replace. Only those glass doors speci cally tested and list-
ed for use with the speci c  replace model should be used.
Screens should be closed when the glass doors are closed
FULLY OPEN
CORRECT
PARTLY CLOSED
INCORRECT
PARTLY OPEN
INCORRECT
FULLY CLOSED
CORRECT
Figure 9.2 Proper Operating Positions of Bi-fold Doors
Fire Risk
Close  rescreen when burning  replace.
Do not use rescreen or glass doors to
hold burning material in  replace.
Firescreen controls sparks.
Glass may break or burning material may
roll out.
WARNING
Fire Risk
Smoke Risk
Doors must be fully opened or fully closed
when operating  replace.
Partially opened doors may draw ame, smoke
or heat from  replace.
WARNING
Asphyxiation Risk
Fire Risk
Open damper to operate  replace.
Closed damper will over- re replace and
prevent venting of combustion gases.
WARNING
B. Clear Space Near the Fireplace
Combustible materials must not be stored on the hearth ex-
tension. Room furnishings such as drapes, curtains, chairs
or other combustibles must be at least 4 ft (1.22 m) from the
open front of the  replace.
C. Flue Damper
The ue damper must be in full open position, and is oper-
ated by moving the handle up toward the top of the replace.
Before lighting the re, verify this by looking up from the in-
side of the replace. Always operate this replace with the
damper fully open. Please note: Down drafts, obstructions,
damaged or poor (wet) fuels can cause smoke spillage.
See Figure 9.1 for location and operation.
E. Glass Doors
Most ef cient replace operation using glass doors is with
the doors open. When the doors are open the screen must
be closed. Only Hearth & Home Technologies glass doors
may be used. See Figure 9.2 for proper glass door opera-
tion.
F. Grate
The factory installed integral grate must be used to hold the
logs from falling out of an open replace and to allow air to
pass between the burning logs. It is important to keep the
re off the hearth and to allow the ashes to collect beneath
the re, thereby forming a layer of additional heat protection.
Fire Risk
Use only factory installed integral grate.
May cause over re.