INSTALLATION WATER HEATER
51
INSTALLATION WITHIN A COVERED AREA
The water heater must be located such that the installation meets the requirements of AS/NZS 5601.1. There
must be sufficient ventilation so the water heater has an adequate supply of combustion air and the flue
products are dispersed safely. It is the licensed installer’s responsibility to ensure the installation complies with
the relevant sections of the prevailing Gas installations Standard.
Installation of this water heater is permitted within a covered area open on at least two sides, if its flue terminal
is located to ensure a free flow of air across it is achieved.
AS/NZS 5601.1 also allows the installation of
a continuous flow gas water heater within a
covered area open on one side only if the flue
terminal is within 500 mm of the opening, is
discharging in the direction of the opening,
there are no openings into the building along
the wall within the 500 mm distance and the
terminal is located to ensure a free flow of air
across it is achieved.
A Rheem 874 or 876 series 812NF, T16NF,
826NF or T26NF model (AU only) fitted with a
Rheem Flue Terminal Diverter (kit number
299287) in accordance with its installation
instructions, can be installed to meet this
requirement.
A Rheem 874 or 876 series 812NF, T16NF, 826NF or T26NF model (AU only) fitted with a Rheem Flue
Terminal Diverter (kit number 299287), or a Rheem 874 or 876 series 826NF or T26NF model (AU only) fitted
with a Rheem Extended Flue Terminal Diverter (kit number 299285), can also be installed on a side wall within
a covered area (open on one side only) and meet the installation requirements of AS/NZS 5601.1, if positioned
so that the outlet of the Flue Terminal Diverter is level with or beyond the outer edge of the side wall of the
covered area.
A Rheem Flue Terminal Diverter or Extended Flue Terminal Diverter can be fitted to these water heaters (AU
only) if installed in a recess box. Refer to
“Recess Installation” on page 52.
812NF, T16NF, 826NF or T26NF 826NF or T26NF
with a Flue Terminal Diverter with an Extended Flue Terminal Diverter
installed in compliance with AS/NZS 5601.1 installed in compliance with AS/NZS 5601.1
PIPE COVER
The pipe work to the water heater can be housed within a pipe cover. A pipe cover kit (Rheem
AU Part 299426, NZ Part 320117) is available for such an installation. Refer to the installation instructions
which accompany the pipe cover kit.
812NF, T16NF, 826NF or T26NF model with a Flue Terminal Diverter
installed in compliance with AS/NZS 5601.1