ABOUT YOUR WATER HEATER
11
GAS BOOSTING FOR A SOLAR WATER HEATER
The 874 series water heater may be installed as an in-series gas booster to a solar water heater.
Water stored in the solar storage tank passes through the in-series gas booster when a hot tap is opened. The
in-series gas booster is for heating water at times of low solar energy gain, such as during cloudy or rainy
weather, or during colder months.
The in-series gas booster operates automatically. When the solar heated water temperature is below 58°C,
the in-series gas booster heats the water to its preset outlet temperature setting.
Solar heated water can reach temperatures up to 70°C to 80°C for a Premier Loline and Loline pumped system
and possibly higher for a Hiline and Premier Hiline thermosiphon system. When the solar heated water
temperature is 58°C or higher, the flow passes through the in-series gas booster without boosting.
For information relating to the function and operation of the solar water heater, refer to the Owner’s Guide and
Installation Instructions supplied with the solar water heater.
REDUCED HOT WATER FLOW WHEN HEAT EXCHANGER IS COLD
At a cold start-up, i.e. when the water heater has not operated for some time (which is most often first thing in
the morning), the initial flow of hot water may be reduced for a period of 5-10 seconds while the heat exchanger
warms up. This is both an energy and water saving feature of this water heater. Once the heat exchanger
has warmed up the hot water flow will increase and remain at normal flow levels. This feature will only occur
at a cold start-up and not when the heat exchanger is already warm from a recent use of hot water.
FROST PROTECTION
The water heater has a frost protection system. The frost protection system will protect the water heater from
damage, by preventing ice forming in the waterways of the water heater, in the event of freezing conditions
occurring.
Notes
The frost protection system will be rendered inoperable if electrical power is not available at the water
heater. Damage caused by freezing due to the unavailability of power at the water heater is not covered
by the Rheem warranty (refer to
“Terms of the Rheem Warranty” on page 4).
If it is necessary to switch the power off to the water heater and there is a risk of freezing, then it is
necessary to drain the water heater (refer to
“Draining the Water Heater” on page 13).
Pipe work to and from the water heater must be adequately insulated to prevent freezing.
The water heater is not suitable for installation in areas where the ambient temperature falls below -20°C
(including wind chill factor).
Refer to
“Terms of the Rheem Warranty” on page 4.
PRECAUTIONS
The water heater must be maintained in accordance with the Owner’s Guide and Installation Instructions. Refer
to “General Maintenance” on page 12 and “Major Service Every Five Years on page 12.
If this water heater is to be used where an uninterrupted hot water supply is necessary for your application or
business you should ensure that you have back-up redundancy within the hot water system design. This should
ensure the continuity of hot water supply in the event that this water heater were to become inoperable for any
reason. We recommend you seek advice from a plumber or specifier about your needs and building back-up
redundancy into your hot water supply system.