P/N AYRD-210-INST-FUL Rev F
Definitions
All Code Lockout Mode: This feature is enabled by the Master code. When enabled, it restricts all user (except
Master) PIN code access. When attempting to enter a code while the unit is in Lockout, the keypad flashes 8
times and the lock beeps 3 times as well.
Audio Mode: Disable (3)Choosing in Audio mode shuts off the code confirmation tone play-back for use in quiet
areas. Audio mode is enabled or disabled through feature programming by the Master code.
Automatic Re-lock Time: After a successful unlock, the unit will automatically re-lock after thirty (30) seconds.
This feature is only available when a Network Module is installed.
Low Battery: When battery power is low, the Status Indicator flashes RED. If battery power is completely lost, use
the key override.
Master PIN Code: It must be createdThe Master PIN code is used for programming and for feature settings.
prior to programming the lock. The Master code will also operate (unlock/lock) the lock.
Network Setting: This setting is available thru the main Menu (7) and allows the lock to connect with a network
controller. It is also available through the wireless button on the interior escutcheon.
One Touch Locking: When the latch is retracted, activating the keypad will extend the latch (during Automatic Re-
lock duration or when Automatic Re-lock is disabled).
Privacy Mode: Privacy mode is disabled by default. Enable Privacy mode by pressing the privacy button for 4
seconds to put the lock in do-not-disturb mode (all pin codes are disabled).
Shutdown Time: The unit will shut down (flashing keypad) for sixty (60) seconds and not allow operation after
the wrong code entry limit has been met.
Tamper Alert: Audible alarm sounds if attempting to forcibly remove outside lock from door.
User PIN Code: The User code operates the lock. Maximum number of user codes is 250 with Network Module;
without Network Module, maximum is 25 user codes.
Wrong Code Entry Limit: After five (5) unsuccessful attempts at entering a valid PIN code, the unit will shut down
and not allow operation.