Weil-McLain AQUABALANCE HEAT-ONLYAB-120H Series 2 High-efficiency Gas Water Boiler

User Manual - Page 74

For AQUABALANCE HEAT-ONLYAB-120H.

PDF File Manual, 136 pages, Read Online | Download pdf file

AQUABALANCE HEAT-ONLYAB-120H photo
Loading ...
Loading ...
Loading ...
Part number 550-100-325/0419
74
AquaBalance
®
Series 2 Wall Mount Gas-fired Water Boiler Boiler Manual
31 Startup Quick Start Guide using default settings (continued)
QUICK START GUIDE
System start (continued)
9
“Test Mode Operation”
Proceed to put the boiler into operation as follows:
1. To start, create a demand for heat, open up a hot water faucet or turn up the thermostat.
2. To operate the boiler in test mode, press the CH “-” and “+” keys together for 5 seconds
(See below and Figure 104, page 79) to activate the TEST mode.
3. The boiler lights at the maximum heating 100% rate displayed on the LCD display.
4. The high fire (large) flame symbol will be displayed once the boiler has lit.
5. Use DHW “_” button to drop firing rate to low fire.
6. To exit the Test mode, press the CH keys (Items 3 and 4, Figure 80, page 62) together for 5 seconds, or
leave the boiler to automatically switch off after 15 minutes or stopping DHW flow.
7. This TEST procedure is used to check/adjust combustion CO and CO
2
per specifications, Figure 107, page 82
and Figure 110, page 83.
Liquefied Petroleum (Propane) Gas — Propane conversion kit (optional - sold separately, see Figure 163, page 120 .
High altitude — High altitude (over 2,000 feet) requires only changing the altitude setting on the control. (See page 70).
Equipment that maybe required for installation
Digital or U-tube manometer for checking gas line pressure.
Volt-ohmmeter may be required for troubleshooting.
Combustion Analyzer to verify and adjust combustion.
This unit must only be used for its intended purpose. This unit is designed to heat water to a temperature below
boiling point and must be connected to a heating system and/or a water supply system for domestic use, compatible
with its performance, characteristics and heating capacity. Any other use is deemed improper.
Incorrect installation can cause damage or injury for which the manufacturer cannot be deemed responsible.
The boiler contains ceramic fiber and fiberglass materials. Use care when handling these materials per instructions
on page 86 of this manual. Failure to comply could result in severe personal injury.
Pay attention when handling the boiler insulation panels as they contain materials that could irritate the skin. No
part of the boiler contains asbestos, mercury or Chlorofluorocarbons (CFC’s).