Control Panel
Fault LightLED Light
• Connect fridge to 12 or 24V DC.
Power Source Cut O Voltage Cut In Voltage
12V DC 10.4V 11.7V
24V DC 22.8V 24.2V
• Ensure correct voltage is applied to run the fridge.
• Set thermostat to the desired setting. We recommend starting at 3. Allow 24 hours for
the cabinet to come down to temperature and settle in.
• To make the fridge colder, turn dial to a high number and to make the fridge warmer
turn to a lower number.
• 0 is the ‘OFF’ position.
• Note: Always allow 24 hours aer any adjustment for temperatures to settle.
Low Ambient Heater
What it does: In low ambient temperatures 12°C and under, there is not enough heat
in the air to cycle the fridge back on, so a heater is needed to assist this to happen. This
operation draws as little as 2.4A/hr.
What do I need to do? Absolutely nothing. The heater is controlled electronically, so
during the colder months the fridge senses when it is needed and activates this function.
Dial
1 = Warmer
7 = Coldest
0 = O