1 Safety Instructions
Warning: Do not use your unit if any cabling is damaged, frayed or exposed.
Warning: Do not attempt or continue to operate your unit if it is wet.
When using the unit ensure the circuit being used has a fuse or circuit breaker, located at
the battery, the recommended size for DC 12 Volt is 15 Amp, DC 24 Volt is 7.5 Amp.
Do not place any electrical devices inside the refrigerator as they may become damaged.
2. Notes On Using The Product
Your unit requires good ventilation; allow a gap of at least 50mm around the refrigerator.
Do not allow a large amount of frost to build up on the inside walls as this may impair
cooling. Defrost regularly by turning the unit o, allowing the frost to melt and wiping
out the water. This fridge is not frost-free, we recommend defrosting your fridge every
one to six months (dependent on variable factors).
The lower the ambient temperature, the lower the power usage. In order to maximise
eiciency keep the unit in a cool location out of direct sunlight.
It is recommended to operate the unit on a flat surface, but it will operate at angles up to
30°.
3. Operation
Power: DC (12 and 24 Volt)
Cable Length Specification
The DC cables must have a suitable cross-section for their length (measured from the
battery to the unit), according to this table:
Cable Thickness (Area) 12V Max Cable Length 24V Max Cable Length
(mm
2
) AWG (m) () (m) ()
2.5 14 2.5 8 5 16
4 12 4 13 8 26
6 10 6 20 12 39
10 8 10 33 20 66
The refrigerator is fitted with an Anderson style plug connection. Ensure cabling to
the fridge is also fitted with this style plug, this will guarantee the best connection and
minimise voltage drop.