INSTALLATION
1. Remove the Room Cabinet from chassis by
lifting up and out to clear mounting brackets.
2. Remove four “a” screws and the cover plate
from the mounting plate.
3. Attach the field supplied conduit to the
mounting plate.
4. Connect Power Supply Conductors to the
Inner Conductors with wire nuts.
5. Dress the wiring inside the compartment
and attach the cover plate.
6. Reinstall the Room Cabinet.
9
208/230 volt model is equipped for connection
with a power cord according to unit capacity at
the time of shipment.
Should local code or special requirements specify
permanent connection of this unit, use adapter kit
RAK-400.
PREPARATION
1. The electrical rating marked on the previously
installed Zoneline must be the same as the
supply branch circuit.
2. The unit provides for connection of 1/2”
trade size electrical conduit and provision for
connection to a wiring system in accordance
with the National Electric Code ANSI/NFPA
No. 70-1993.
Electrical
Junction Box
Wire Nut
Cover Plate
FOR 208/230 VOLT UNITS
All 265V units are direct connected and come
with the cover plate and mounting plate (junction
box). The conduit is field-supplied by the installer.
FOR 265 VOLT UNITS
Inner Conductors
Power Supply
Conductors
Mounting
Plate
a
PERMANENT CONNECTION