FOR TECHNICAL SUPPORT DIAL OUR TOLL FREE NUMBER:
1-800-528-2806
NOTICE: To comply with FCC and/or Industry Canada (IC) rules, adjustment or modifications
of this receiver are prohibited. THERE ARE NO USER SERVICEABLE PARTS.
This device complies with Part 15 of the FCC rules and IC RSS-210. Operation is subject to
the following two conditions: (1) this device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may cause
undesired operation.
SPECIFICATIONS
System Capacity (Pass Through and Advanced).............................. 12,000 devices
Supply Voltage ....................................................... 12 -24 dc
Operating Current ..................................................... 250 mA Maximum
Stand By Current...................................................... 30 mA Maximum
Surge Suppression .................................................... 6.0kV Min
Operating Temperature Range ........................................... -40°C to +65°C @ 50% Rh, (-40°F to +149°F @ 50% Rh)
Storage and Shipping Temperature Range .................................. -40°C to +85°C @ 50% Rh
Compatible Code Format................................................ Security+ 2.0
®
Wiegand Data format .................................................. 26 Bit, 30 Bit, 31 Bit, 34 Bit (Even or Odd), and 50 Bit
Wiegand Output ...................................................... 5 Vdc, Open Collector
REPAIR PARTS
Straight Antenna ........................... K76-36681
Mounting Bracket .......................... K13-36651-2
COMPATIBLE ACCESSORIES
Remote Controls:
Passport MAX............ PPV3M, PPK3M, PPK3PHM
Passport Lite............. PPLV1-X, PPLK1-X, PPLK1PH-X
(X refers to 10 or 100 packs)
Antenna Extension Kits:
15' Extension Kits ......... 86LM
25' Extension Kits ......... 86LMT
Transformer:
12-24 Vdc ............... 95LM, 002A1699-1
ONE YEAR LIMITED WARRANTY
LiftMaster warrants to the first consumer purchaser of this product that it
is free from defect in materials and/or workmanship for a period of 1 year
from the date of purchase.
DIAGNOSTICS
The PPWR receiver was designed to emit a series of audible beeps
dependent on programming and error conditions. The table below lists all
of the event conditions and related audible beep notifications. Audible
notifications may be disabled in the “BEEP SETTINGS” menu.
EVENT BEEP
Key press Single
Successful add/change Double
Successful delete Triple
Master PIN entry error Long
Programming error Long
Generic success Double
Generic error Long