Appliance description
www.bora.com
4.3.2 Sensors
The cooktop extractor is equipped with sensors in the area of
the cover flap and the grease filter.
Cover flap position sensor
The cover flap sensor detects the position of the cover flap.
XO
If the cover flap is closed, the cooktop extractor is
deactivated.
XO
If the cover flap is open, the cooktop extractor can be used.
XO
If the cover flap has been removed, the cooktop extractor can
be used.
Grease filter position sensor
The grease filter sensor detects whether the grease filter has
been fitted correctly. If the grease filter is missing or has been
fitted incorrectly, the cooktop extractor is deactivated.
i
If the grease filter is removed, for example, for cleaning,
the cover flap can still be closed.
4.3.3 Interface for external devices
The internal interface can be used for extended control options.
This has a Home In and a Home Out contact (see the Installation
chapter).
XO
The Home In contact can be used for the signal input from
external switch devices (e.g. window contact switch).
XO
The Home Out contact can be used to control external
installations (e.g. electrically opening wall sleeves).
4.3.4 USB port for servicing
The system has a USB port for servicing. This port is only
suitable for mass storage devices (USB sticks). These USB sticks
must be formatted with the FAT32 data system.
i
The USB port is only designed for updates or data export
and only has sufficient power supply for these processes.
It is not possible to charge devices or carry out other
functions.
Cooktop extractor system PKAS3/PKAS3AB
6
5
4
3
2
1
Fig. 4.6 Cooktop extractor system PKAS3/PKAS3AB
[1] Cover frame
[2] Holding plate
[3] Control unit
[4] Fan housing with fan
[5] Control knob
[6] Cover flap
Grease filter components
4
3
2
1
Fig. 4.7 Grease lter components
[1] Cover flap
[2] Stainless steel grease filter
[3] Filter tray