Page 16 of 40 802005 - Sparkling HT-BCS; CS; AIO; Residential- Installation Instructions - June 2015 - v2.01
Air Filter Change:
The Zip HydroTap air filter is conveniently located on the outside of the condenser.
The filter screen is a sliding fit in the plastic housing on the left hand side of the under
sink unit. The screen may be removed for cleaning, by sliding it forward. This needs
to be inspected at least quarterly, cleaned and replaced if damaged.
Note
:
For best performance the unit should only be operated with a clean air filter
screen, correctly fitted in place. Maintain, at least, a 50mm air gap in front of the
screen at all times. Take care not to allow cloths or other soft materials to accidentally
block the air inlet.
Slide to remove
Filter
CO2 Gas Bottle Replacement
Gas Bottle Replacement:
1. Turn off the water and power supply to the chilled sparkling unit.
2. Turn off the regulator on top of the bottle. The regulator has a left hand
thread, to turn off, turn anticlockwise until shut.
3. Remove the CO2 bottle from its mounting and unscrew the bottle from the
regulator. The braided hose may be left connected to the regulator, or, for
convenience, removed and refitted to the regulator and new bottle.
4. Connect the new bottle to the regulator. Be aware that some CO2 may be
discharged from the connection to the regulator when the bottle and the
regulator are assembled together. Any CO2 released will be cold.
5. Ensure the braided hose is correctly fitted to the regulator, with the sealing
olive in place, before turning on the gas.
6. Turn the regulator on and adjust to 2.7- 3.0 bar.
7. Turn the sparkling lever to the on position. Leave it on until all the water
has been purged through the tap. Let the tap run for a further 10 seconds to
purge the CO2 through the tank. Turn off the sparkling lever.
8. Turn on the cold water supply first and then the power supply.
9. Wait 20 seconds and then turn on the sparkling lever and wait for water to
start to come through.
10. Dispense some sparkling water from the tap. Perform a taste test.
Service
There are no user serviceable parts but there are dangerous voltages present
within the unit. All service work must only be carried out by a suitably qualified and
experienced service person.
Before calling for service, check that both the water and electricity supplies are turned
‘ON’ and OK.
Call a licenced electrician, plumber, or Zip for a free call in Australia on 1800-
638-633, for assistance, service, spare parts, or enquiries.