Wiring the heating panel sets
1. Once mats are installed properly,
recheck mat resistance using Ohm
Meter to ensure that no damage
occured.
2. Run all leads to a junction box. To
make the appropriate connections,
wire the heating panels in parallel.
Installation & Owner’s Guide QW-JOIST 7
CAUTION:
RISK OF ELECTRIC SHOCK AND FIRE DAMAGE
TO THE SUPPLY CONDUCTOR INSULATION
MAY OCCUR IF CONDUCTORS ARE ROUTED
LESS THAN 2 INCHES (51 MM) FROM THIS
HEATING PRODUCT. REFER TO INSTALLATION
INSTRUCTIONS FOR FOR RECOMMENDED
MEANS OF ROUTING SUPPLY CONDUCTORS.
CAUTION:
Route and secure wires between the
heating panels, from the heating panels
to the thermostat box and from the
thermostat box to the electrical panel
using standard wiring practices that
conform to all of the requirements of all
applicable electrical and building codes.