PROPANE SAFETY
Propane is safe to use when properly handled.
Careless handling of the Propane gas tank could
result in re and/or an explosion. Therefore:
Always keep tank/cylinder securely fastened
in an upright position.
Avoid tipping tank on its side when
connected to a regulator since this may
cause damage to diaphragm in regulator.
Handle valves with care.
Never connect an unregulated Propane tank
to construction heater.
Do not subject Propane tank to excessive
heat.
Tightly close the gas shutoff valve
THE DISCONNECTED TANK MUST NEVER
BE STORED IN A BUILDING, GARAGE
OR ANY OTHER ENCLOSED AREA.
LEAK CHECKING
Check all gas connections with a soap solu-
tion to be sure they are tight and leak proof.
• The installation of your heater must meet
all local codes and/or gas utility require-
LIGHTING INSTRUCTIONS
1. Connect power cord to a properly
grounded three (3) prong 120V, 60Hz,
single phase receptacle or insert DC bat-
tery as previously instructed.
2. Turn gas valve knob clockwise to the
minus sign “—” position.
3. Wait ve (5) minutes to clear any gas.
Then smell for gas. If you don’t smell
gas, go to next step
4. Turn gas supply ON by turning propane
tank valve counterclockwise .
WARNING: Motor and fan must be
running before lighting, during operation
and shutdown, in order to prevent a
ame-out condition which could result in
personal injury or property damange.
on the Propane tank after each use.
The POL tting must be protected when
disconnected from the propane tank.
Never store a Propane gas tank inside a
building or in the vicinity of any gas burning
appliance.
ments or, in the absence of local codes, with
the Storage and Handling of Liqueed Petro-
leum Gases, ANSI/ NFPA 58 and the Natural
and Propane Installation Code, CSA B149.1.
5. Toggle the ON/OFF switch to the ON “ |
” position. Keep the gas control knob at
the minus
sign “—” position.
6. Fully depress the ignition button “
” and
hold until the electric spark lights the
burner.
7. Keep the ignition button “ ” pressed for
at least 30 seconds after the burner is lit.
After 30
seconds, release the ignition button.
8. If burner does not stay lit, repeat the
lighting procedure.
9. When burner is lit, turn gas valve knob
counterclockwise to desired setting.