Check that all connections are tight. Small leaks in the tank,
hoses,connections or transfer tubes will substantially reduce the
air compressor and tool performance. Spray a small amount of
soapy water around the area of suspected leaks with a spray
bottle. If bubbles appear, repair: replace or reseal the faulty
component. Do not over-tighten any connections.
Before storing the air compressor compressor:
Drain tank (page 12).
Use an air blow gun to clean all dust and debris from the
pressor.
Disconnect and wind up the power cord.
Clean the ventilation openings on the motor enclosure with
a damp cloth.
Drain all moisture from the tank.
Pull the pressure safety valve to release all pressure from the
tank.
Cover the entire unit to protect it from moisture and dust.
Store the air compressor in a clean and dry location.
In cold weather, store the compressor in a warm building when
it is not in use. This will reduce problems related to starting the
motor and the freezing of water condensation.
Pull/actiate the safety valve daily to ensure that it is operating
properly and to clear the valve of any possible obstructions.
DESCRIPTION / REASON
SERVICE
INTERVAL
ITEM
Through normal operation of your air compressor,
conndensation water will accumulate in the tank. To prevent
corrosion of the tank from the inside, condensation must be
drained at the end of every workday. Be sure to wear protective
goggles. Relieve the air pressure in the system then open the
ball valve on the bottom of the tank to drain. Under cold
conditions it is especially important to drain the tank after each
use to reduce the chance of problems resulting from the freezing
of condensation water.
NOTE: Refer to instructions on how to drain tank (page 12).
Drain the
tank
Check the
valve
Test for
leaks
Storage
Daily
Daily
Monthly
Prior to
storing
Maintenance
Storing and moving the Air Compressor
CAUTION
Unlock
2
For storage only
1
To avoid personal injury, DO NOT grab only the
sliding handle (1) to lift the whole unit. If you want
to lift the unit, please make sure you grab both the
tank and sliding handle (1). Use the following
instructions to use the sliding handle (1) and
wheels to move the unit.
a.Unlock the two cam locks (2) as shown in the
illustration.
b.Slide the handle (1) upward to the desired height.
c. Lock the two cam locks (2) in place.
Loading ...