Dimplex ECSI100-580 100L Indirect Cylinder

User Manual - Page 27

For ECSI100-580.

PDF File Manual, 40 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Installat
ion and User Instructions R01127
-
2 06
/11
Page 27
Technical Data
Figure 12: Indirect Cylinder and Cross-section (for reference only)
Indirect Cylinder Range
Reference
100 125 150 175 210 250 300
Weight (full) [kg]
(+)
120
+
150
+
180
+
210
+
252
+
300
+
360
+
Reheat time [mins]
22* 28# 33# 29# 34# 41# 49*
Heat Loss [kWh]
y
0.9
y
1.0
y
1.2
y
1.3
y
1.4
y
1.7
y
1.9
y
Height [mm] 810 960 1130 1280 1504 1780 2080
Outer Diameter [mm] 580 580 580 580 580 580 580
HW Outlet [mm] 580 730 900 1050 1275 1550 1850
T&P valve [mm] 580 730 900 1050 1275 1550 1850
CW Inlet [mm] 190 190 190 190 190 190 190
Bottom Immersion [mm] 208 208 208 208 208 208 208
Indirect Return [mm] 190 190 190 190 190 190 190
Indirect Flow [mm] 325 325 325 405 405 405 405
Bottom Thermostat [mm] 430 430 430 430 430 430 430
Table 6: Indirect Cylinder Dimensions
Note: All measurements are taken from the base of the cylinder to the mid point on the item.
* Determined in accordance with EN12897.
+
Calculated value.
y
Heat loss figure calculated based on measured surface temperatures. Indicative only.
# Calculated based on measurements.
Loading ...
Loading ...