PelPro Pellet Stove • 7104-171C • 10/3/18 pelprostoves.com26
Replacement Parts
1
Zone
1
Zone
2
Zone
2
Zone
3
Zone
3
Zone
Combustion Blower
1. Turn the dial control to the o󰀨 position. Unplug the
power to the unit.
2. Remove the right side panel by loosening the three
screws attaching it to the back of the appliance.
3. Using a 7/16 wrench or socket, remove the 2 nuts
holding the blower to the convection plenum
4. Lower the back of the blower and lift out.
5. With the blower removed, unplug its wires from the
wire harness.
6. Remove the screws holding the retainer plate to the
convection blower housing.
7. To replace, put the bottom lip of the blower into
the lower slot. Attach the top of the blower to nuts.
Reattach the metal plate and screw nuts into bolts.
8. Attach wires to wire harness.
9. Attach the right side panel and tighten screws.
Replacement kit: KS-5020-1052
Exhaust Blower
1. Turn the dial control to the o󰀨 position. Unplug the power to the unit.
2. Remove the left side panel by loosening the three screws attaching it to the back of the
appliance.
3. Disconnect 2 white wires from the blue wires of the exhaust blower.
4. Remove the blower motor attached to a removable plate on the exhaust blower.
Depending on the model, use a 1/4 inch socket, or 1/4 inch Nut Driver or #2 Phillips Head
screw driver to loosen the 6 screws in the keyhole shaped holes and rotate the plate. It is
only necessary to loosen screws.
5. Remove the exhaust blower and gasket.
6. Check for degradation on the gasket and replace if necessary using the gasket included in
the kit.
7. Re-install in reverse order.
Replacement kit: 812-4400