Pre-Installation
HP Cylinder
Installatio
n and User Instructions R03184
-4 09/15
Page
15
Table 2: Sizing of Copper Discharge Pipe “D2” for Common Temperature Relief Valve Outlet Sizes
3.4.2 Worked Example
This example is for a temperature
relief valve with a discharge pipe (D2)
(as fitted on 125 to 300L cylinders)
having 4 No. 22mm elbows and length
of 7m from the tundish to the point of
discharge.
From Table 2, the maximum resistance
allowed for a straight length of 22mm
copper discharge pipe
(D2) from a temperature relief
valve is 9.0m. Subtract the resistance
for 4 No. 22mm elbows at 0.8m each
= 3.2m.
Therefore the maximum permitted
length equates to 5.8m, which is less
than the actual length of 7m, therefore
calculate the next largest size.
Maximum resistance allowed for a
straight length of 28mm copper
discharge pipe (D2) from a
temperature relief valve is: 18m
Subtract the resistance for 4 No. 28mm
elbows at 1.0m each = 4m
Therefore the maximum permitted
length equates to 14m.
As the actual length is 7m, a 28mm
(D2) copper pipe will be satisfactory.
Loading ...