Genie 4042-TKH SilentMax 1200 3/4 HP Belt Drive Garage Door Opener

ASSEMBLY/INSTALLATION - Page 8

For 4042-TKH.

PDF File Manual, 8 pages, Read Online | Download pdf file

4042-TKH photo
Loading ...
Loading ...
Loading ...
11a. Install light bulbs into powerhead (F).
NOTE: DO NOT exceed maximum wattage. Each light bulb should be no more than 100W
11b. Insert powerhead lens hinge (E) into slots in motor cover on powerhead (F).
11c. Swing lens (E) up into place. It may be necessary to squeeze lens slightly to align tabs
with slots at top of motor cover.
11d. Insert rubber plugs (in orange bag) into powerhead accessory holes if present.
NOTE: Remove and discard foam
cushion at this time.
Each light bulb must be 100W or less
Motor cover
F
Compact CFL bulbs can be used.
11a
F
E
11b
Tab
11c
11d
Rubber plugs
LIGHT ASSEMBLY
Refer to PAGES 7-8 of the Operation and
Maintenance Manual for programming instructions.
CAUTION
DO NOT run operator until travel limits have been set to avoid damage to unit.
For Grounded Outlet Connection:
12a. Plug in the power cord. Coil excess cord and tape or twist tie it to top of
powerhead. (DO NOT PLACE ABOVE LIGHT BULBS.)
For Permanent Wiring by an Electrician:
12a. Cut existing wires OUTSIDE CHASSIS.
12b. The wire connections must be made INSIDE CHASSIS and there must be at least 6" of new power supply
line wire INSIDE CHASSIS. (Conduit is optional. Conduit, strain relief, and wire nuts are not provided.)
WARNING
Operator is equipped with grounded electrical plug for your protection, and only ts grounded electrical
outlets. DO NOT alter plug in any way! If you have no grounded outlets, have one installed by a
licensed electrician. Operator must be properly grounded to prevent personal injury and equipment
damage. NEVER USE AN EXTENSION CORD! Check local building codes for any requirement that you must
have a permanent hard-wired connection. NEVER REMOVE MOTOR COVER. All work inside cover must
be performed by a licensed electrician using proper tools and instructions.
Hot
Neutral
GroundGround
Wire nuts
12b
NOTE: After power is supplied to the powerhead: (1) Check if the red and green Safe-T-Beam
®
LEDs are lit. If not,
return to step 9 and check wiring. (2) See if wall console red LED is lit. If not, check if a blue LED on powerhead
is blinking. If yes, press the "LOCK" button on the wall console. (Wall console LED should now be lit.) Otherwise,
return to step 10 and check wiring.
CONNECTING POWER
YOU ARE NOW READY TO PROGRAM!