ELECTRIC DRYER ELECTRICAL CONNECTIONS
Power Supply Cord Connection (cont.)
2. Insert power cord into strain relief.
Put power supply cord through the strain relief. Be sure that the wire
insulation on the power supply cord is inside the strain relief. The
strain relief should have a tight fit with the dryer cabinet and be in a
horizontal position. Do not further tighten strain relief screws at this
point.
Connecting 4-Wire Connection: Power Supply Cord
IMPORTANT: A 4-wire connection is required where local codes do
not permit the use of 3-wire connections.
Standard Power Supply Cord Connectors
Flanged spade connector Ring Connector
Connecting Ground and Neutral Wires
1. Remove center terminal block screw (A) and neutral ground
wire (B) by removing the external ground connector screw (C).
2. Connect neutral ground (B) and neutral wire (white or center) (D)
to center terminal block. Tighten screw.
Connecting Power Cord Ground Wire
3. Connect ground wire (green or bare) (E) with external ground
connector screw (C). Tighten screw.
Connecting Remaining Wires
4. Connect remaining wires with outer terminal block screws (F).
Tighten screws. Finally, re-install terminal block cover and tighten
hold-down screw. Go to “Complete Installation” section.
Connecting 3-Wire Connection: Power Supply Cord
Standard Power Supply Cord Connectors
Flanged spade connector Ring Connector
Connecting Neutral Wire
1. Loosen or remove center terminal block screw (A).
A
C
B
B
D
C
E
F
F
A
Loading ...
Loading ...