You will be required to select a Maximum Runback Duration, this value can be
selected from the pre programmed list. Each Max Duration will provide four
selectable runback periods. See the table below for a break down of the options
available:
Use the arrow keys to select to the desired runback time. Press ENTER to confirm
and move onto Runback temperature settings.
Use the arrow keys to select the desired Runback temperature. Press ENTER to
activate the Runback timer and return to the home screen.
Maximum
Runback
Duration
Selectable Runback options
Period 1 Period 2 Period 3 Period 4
0:30 0:15 0:20 0:25 0:30
1:00 0:15 0:30 0:45 1:00
1:30 0:15 0:30 1:00 1:30
2:00
(default)
0:30 1:00 1:30 2:00
4:00 1:00 2:00 3:00 4:00
6:00 1:30 3:00 4:30 6:00
8:00 2:00 4:00 6:00 8:00
NOTE:
When activated the temperature set-point which has been set during the mode
setup (above) will be active. This value can be adjusted temporarily during runback
mode operation by using the arrow keys.