INSTALLATION INSTRUCTIONS
Installing in an alcove, closet, or wall insert/recessed
If you install your dryer in an alcove, closet, or wall insert/recessed, the front of the
closet must have two unobstructed air openings for a combined minimum total
area of 72 sq.in. (465 sq. cm) with a minimum clearance of 3 in. (7.6 cm) at the top
and bottom. A slatted door with equivalent space clearance is acceptable.
Minimum clearances between your dryer and adjacent walls or other surfaces are:
Either side: 1 in. (2.5 cm)
Rear: 5 in. (12.7 cm)
Top: 24 in. (61 cm)
Front: 2 in. (5.1 cm)
WARNING:
You must exhaust your dryer to the outside to reduce the risk of fire when
installed any place inside the house.
Do NOT install another fuel-burning appliance in the same closet as your
dryer.
For information about how to select and install exhaust ducts, see Exhausting
requirements on page 15.