electrical information
6.5 control module operation
1. The control module has an ON/OFF/
REMOTE selector switch that must be set
(see Figure 9).
OFF Position: Appliance will ignore all
power inputs and will not respond to
any commands from a wall switch or
transmitter. The unit should be in the OFF
position during installation, service, fuel
conversion, and if the control goes into
LOCK-OUT mode as a result of an error
code.
ON Position: Appliance will ignite and
run continuously. This mode of operation
is primarily used for initial installation.
REMOTE Position: Appliance will initiate
commands from an optional wall switch
and/or the wireless transmitter.
2. If you intend to use both an optional wired
wall switch and the transmitter to operate
your fireplace, the wall switch will override
any commands given by the transmitter.
3. Module Reset: This module may lock-out under certain conditions. When this occurs, the appliance will not
ignite or respond to commands. The module will go into lock-out mode by emitting three audible beeps, then
continuously displaying a RED/GREEN error code at its status indicator LED.
Turn the gas manual shut-off valve clockwise to the “OFF” position. (Shut-off valve is located on the flex
connector).
Set the module selector switch to the OFF position.
Wait five (5) minutes to allow possible accumulated gas to clear.
Turn the manual shut-off valve counterclockwise to the “ON” position
Set the module selector switch to ON or REMOTE position.
Start the appliance.
4. Setting the Child Lock: Slide the battery cover down from the back of the transmitter. Slide the child lock
switch to enable or disable the child lock feature.
!
WARNING
Risk of Explosion! DO NOT reset the module more than once within a five-minute time period. Gas may
accumulate in firebox. Call a qualified service technician.
Figure 9
LEARN
MODULE
SELECTOR
SWITCH
STATUS
NG/LP
GAS-TYPE
FLAME HI/LO
No functions will be usable until child lock feature is disabled.
note:
Your appliance has been equipped with an LED (light) strip which is programmed with three colour modes. Plug the
LED power supply into a GFI protected electrical outlet.
Turn on the light switch located under the access panel and toggle the switch off and on to cycle through the desired
mode.
Mode 1 - Simulated white.
Mode 2 - Continuous 2 colour shift. Takes 8-10 seconds to smoothly ramp up one colour to 100%, as the other
fades off from 100% to 0. Continually shifts in colour (17 seconds per colour, up and back down).
Mode 3 - Freeze Mode Colour stops the colour shift on whichever colour it was on in Mode 2 at the time it was
turned off; does not continue to shift.
Switch off for 10 seconds to reset to beginning colour mode.
note:
6.6 LED light operation