Napoleon GVF36-2N Grandville VF36

User Manual - Page 7

For GVF36-2N.

PDF File Manual, 30 pages, Read Online | Download pdf file

GVF36-2N photo
Loading ...
Loading ...
Loading ...
EN
W415-0297 / R / 02.23.21
7
general information
1.4 rating plate information
CERTIFIED TO: ANSI Z21.11-2019 UNVENTED HEATERS
W385-0247 / I
SERIAL NUMBER: GVF36
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
THIS APPLIANCE MAY BE INSTALLED IN AN AFTERMARKET,
PERMANENTLY LOCATED, MANUFACTURED (MOBILE) HOME, WHERE
NOT PROHIBITED BY LOCAL CODES. THISAPPLIANCE IS ONLY FOR USE
WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE. THIS
APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES.
THIS IS A GAS-FIRED UNVENTED ROOM HEATER THAT REQUIRES
ADEQUATE COMBUSTION AND VENTILATION AIR. THIS UNIT IS NOT
APPROVED FOR BEDROOM, BATHROOM AND BED-SITTING ROOM
INSTALLATION.
GVF36N CVF36N MODEL GVF36P CVF36P
**0-2000FT (0-610m) ALTITUDE 0-2000FT (0-610m)**
30,000 BTU/h INPUT 30,000 BTU/h
20,000 BTU/h REDUCED INPUT 22,000 BTU/h
MANIFOLD PRESSURE: 3.5" WATER COLUMN MANIFOLD PRESSURE: 10" WATER COLUMN
MINIMUM SUPPLY PRESSURE: 4.5" WATER COLUMN MINIMUM SUPPLY PRESSURE: 11" WATER COLUMN
MAXIMUM SUPPLY PRESSURE: 7.0" WATER COLUMN MAXIMUM SUPPLY PRESSURE: 13" WATER COLUMN
SIT CONTROL: #820637 SIT CONTROL: #820636
OPERATING PILOT OXYPROTECTOR: #8214 OPERATING PILOT OXYPROTECTOR: #8404
**
ABOVE 2,000FT, CONSULT LOCAL AUTHORITY HAVING JURISDICTION
NOT FOR USE WITH SOLID FUEL.
WARNING: FIREPLACE SCREENS MUST BE CLOSED WHILE IN OPERATION.
DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH
WILL COME IN CONTACT WITH THE FLAMES, OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE. DO NOT USE BLOWER INSERT, HEAT EXCHANGER
INSERT OR OTHER ACCESSORIES NOT APPROVED FOR USE WITH THIS HEATER. IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTAINANCE CAN
CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. REFER TO THE OWNER'S INFORMATION MANUAL PROVIDED WITH THIS APPLIANCE. INSTALLATION AND
SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER. THIS APPLIANCE IS INTENDED FOR SUPPLEMENTAL HEATING. FAN
TYPE UNVENTED HEATER.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS:
TOP / SIDES / BACK / FLOOR 0”
RECESSED DEPTH 13
1
/
2
MANTEL 8”*
* MINIMUM CLEARANCE TO A COMBUSTIBLE MANTLE IS 12” WHEN USING A
CATALYTIC DOOR. MAXIMUM HORIZONTAL EXTENSION: 2". SEE INSTRUCTION
MANUAL FOR GREATER EXTENSIONS.
ELECTRICAL RATING: 115V 0.82AMP, 60HZ
OPTIONAL FAN KIT: GZ550-KT
9700539 (WSL) 4001657 (NGZ)
4001658 (NAC) 4001659 (WUSA)
Refer to the Intertek Directory of Building Products (https://bpdirectory.intertek.com) for detailed information
8 CA8 CANADNAD
NN
STISTIONON
AA
EE
DRDR
OOOO
MM
0-200-2000FT00FT (0- (0-610m610m
0000 B00 BTU/hTU/h
NPUNPUT T
0 B0 BTU/hTU/h
PL
PL
MANIMANIFOLDFOLD PRE PRESSUSSU
AA
IIMUM MUM SUPPSUPPLYLY
N N
MAXIMAXIMUM MUM SUPSUP
7 7
SIT SIT CONTCONTROL:ROL:
#8#8
OPEROPERATINATING PIG PILOT LOT OO
NSUNSULT LLT LOCALOCAL AUT AUTHORIHORITY HTY HAVINAVINGG
OOR R USUSE E WIWITHTH S SOLOLIDID
SSED ED WHIWHILE LE IN IN
AAT SUT SUPPLIPPLIED BED BY THY THE MAE MANUFANUFACTUCTU
SESE WIT WITH THH THIS HIS HEATEEATER. IR. IMPRMPR
OOF LIF LIFE. FE. REFEREFER TOR TO THE THE OWN OWN
, , SERVSERVICE ICE AGENAGENCY OCY OR THR TH
RIARIALS:LS:
57 57 (N(N
6659 59
(WU(WU
dding ing ProdProductsucts (ht (https:tps://bp//bp
1.5 mobile home installation
This appliance must be installed in accordance with the manufacturer’s instructions and the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States or the Mobile Home
Standard, CAN/CSA Z240 MH Series, in Canada. This appliance is only for use with the type(s) of gas
indicated on the rating plate.
This mobile/manufactured home listed appliance comes factory equipped with a means to secure the appliance. Built
in appliances are equipped with 1/4” (6.4mm) diameter holes located in the front left and right corners of the base.
Use appropriate fasteners, inserted through the holes in the base to secure. For free standing products contact your
local authorized dealer / distributor for the appropriate securing kit. For mobile home installations, the appliance must
be fastened in place. It is recommended that the appliance be secured in all installations. Always turn off the pilot and
the fuel supply at the source, prior to moving the mobile home. After moving the mobile home and prior to lighting the
appliance, ensure that the logs are positioned correctly.
This appliance is certifi ed to be installed in an aftermarket permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible
for use with other gases, unless a certifi ed kit is used.
Conversion Kits
This appliance is fi eld convertible between Natural Gas (NG) and Propane (P).
To convert from one gas to another, consult your Authorized dealer/distributor.
note:
Conversion kits are not available for Vent Free appliances.
Loading ...