Napoleon GVF36-2N Grandville VF36

User Manual - Page 5

For GVF36-2N.

PDF File Manual, 30 pages, Read Online | Download pdf file

GVF36-2N photo
Loading ...
Loading ...
Loading ...
EN
W415-0297 / R / 02.23.21
5
standard checklist
1.0 general information
NATURAL GAS PROPANE
Altitude (FT) 0-4,500
Max. Input (BTU/HR) 30,000
Min. Inlet Gas Supply Pressure 4.5" Water Column 11" Water Column
Max. Inlet Gas Supply Pressure 7" Water Column 13" Water Column
Manifold Pressure (Under Flow Conditions) 3.5" Water Column 10" Water Column
When the appliance is installed at elevations above 2,000ft, and in the absence of specifi c recommendations
from the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of
4% for each additional 1,000ft.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible
for use with other gases.
No external electricity (110 volts or 24 volts) is required for the gas system operation.
Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.
This appliance is equipped with a pilot light safety system referred to as an oxygen depletion sensor and is
designed to turn off the appliance if not enough fresh air is available.
Use only accessories designed for and listed with your specifi c appliance.
This appliance is intended for supplemental heating.
Ceiling fans or oscillating type fl oor fans can cause fl ame impingement if directing air at the appliance. Impinging
ames will cause soot or carbon that may enter into living area. Try reversing ceiling fan or re-directing fl oor fans
to prevent sooting.
The GVF36 is rated at 30,000 BTUs per hour and therefore requires a minimum unconfi ned space of 1,500 cubic
feet.
1.1 combustion and ventilation air provisions
Installer, please fi ll out the following information:
Customer: ______________________________________________________________
Address: ______________________________________________________________
Date of Installation: ______________________________________________________________
Location of Appliance: ______________________________________________________________
Installer: ______________________________________________________________
Dealer/Distributor Contact Number: ______________________________________________________________
Serial #: ______________________________________________________________
This appliance shall not be installed in a confi ned space or unusually tight construction unless provisions are provided for
adequate combustion and ventilation air.
The National Fuel Gas Code, ANSI Z223.1
/ NFPA 54 defi nes a confi ned space as a space whose volume is less than 50
cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space
and an unconfi ned space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per
kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space
in which the appliances are installed, through openings not furnished with doors are considered a part of the unconfi ned
space.
1.2 rates and supply pressure
WARNING
This appliance is equipped for:
Natural gas Propane
Field conversion is not permitted.