SI 6TU - SI 18TU
1 Type and order code
SI 14TU SI 18TU
2Design
2.1 Model Universal Universal
2.2 controller Intern Intern
2.3 Thermal energy metering Integreated Integreated
2.4 Installation location / degree of protection according to EN 60 529 Indoors / IP 21 Indoors / IP 21
2.5 Performance levels 1 1
3 Operating limits
3.1 Heating water flow
1
°C
1. If necessary, the operating range can be extended to a brine inlet temperature of -10 °C. In this case, the minimum brine concentration must be adjusted to 30%. (Freezing tem-
perature -17 C°). At brine inlet temperatures of -10 °C to -5 °C, flow temperature rising from 55 °C to 62 °C.
20 to 62 ±2 20 bis 62 ±2
3.2 Brine (heat source) °C
Antifreeze
Minimum brine concentration (-13 °C freezing temperature)
1
-5
1
to +25
2
Monoethyleneglycol
25 %
1
2. Operation is possible at brine inlet temperatures of up to + 35 °C. At brine inlet temperatures of +25 °C to +35 °C, flow temperature falling from 62 °C to 55 °C.
-5
1
to +25
2
Monoethylenglykol
25 %
1
4 Performance data / flow rate
3
3. These data indicate the size and capacity of the system according to EN 14511. For an analysis of the economic and energy efficiency of the system, the bivalence point and
controller should be taken into consideration. The specified values have the following meaning, e.g. B0/W35: Heat source temperature 0 °C and heating water flow temperature
55 °C. These specifications can only be achieved with clean heat exchangers. Information on maintenance, start-up and operation can be found in the respective sections of the
installation and operating instructions.
4.1 Heating water flow rate at internal pressure differential
max.
(EN14511) m³/h / Pa
minimal m³/h / Pa
2,4 / 10700
1,2 / 2700
3,0 / 18000
1,5 / 4500
4.2 Heat output / COP EN 14511 EN 14511
at B-5 / W45 kW / --- 11,5 / 3,3 14,9 / 3,2
at B0 / W55 kW / --- 12,8 / 3,0 16,5 / 2,9
at B0 / W45 kW / --- 13,3 / 3,8 17,0 / 3,6
at B0 / W35 kW / --- 13,9 / 5,0 17,5 / 4,7
4.3 Sound power level to EN 12102
4
dB(A)
47 50
4.4 Sound pressure level at a distance of 1 m
4
5
dB(A)
4. The specified sound levels apply if the supporting feet (available as an option) are not used. If the supporting feet are used, the level can increase by up to 3db (A).
5. The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation with a flow temperature of 35°C. The specified sound pressure level
represents the free sound area level. The measured value can deviate by up to 16 dB(A), depending on the installation location.
35 38
4.5 Brine flow with internal pressure differential heat source m³/h / Pa 3,4 / 14000 4,3 / 21500
5 Dimensions, connections and weight
5.1 Device dimensions without connections
6
H x W x L cm
6. Note that additional space is required for pipe connections, operation and maintenance.
845 x 650 x 565 845 x 650 x 665
5.2 Device connections for heating system Inches
G 1 1/4“ AG
7
7. Flat-sealing
G 1 1/4“ AG
7
5.3 Device connections for heat source Inches
G 1 1/4“ AG
7
G 1 1/2“ AG
7
5.4 Weight of the transportable unit(s) incl. packaging kg 140 163
5.5 Refrigerant; total filling weight type / kg R410A / 4,4 R410A / 5,2
5.6 Lubricant; total filling quantity type / litres
Polyolester
(POE) / 1,2
Polyolester (POE)/ 1,9
6 Electrical connection
6.1 Supply voltage; fuse protection V / A 3~ / PE 400V (50Hz) / C13A 3~ / PE 400V (50Hz) / C16A
6.2 Control voltage; fuse protection V / A 1~ / N / PE 230V (50Hz) / C13A 1~ / N / PE 230V (50Hz) / C13A
6.3 Nominal power consumption
B0 / W35 / max. power consumption
3
kW
2,78 / 5,4 3,72 / 7,2
6.4 Starting current with soft starter A 23 28
6.5 Nominal current B0 / W35 / cos A / --- 5,02 / 0,8 6,71 / 0,8
7 Complies with the European safety regulations
8
8. See CE declaration of conformity
8
8 Additional model features
8.1 Heating water in device protected against freezing
9
9. The heat circulating pump and the heat pump manager must always be ready for operation.
Yes ja
8.2 Max. operating overpressure (heat source/heat sink) bar 3,0 3,0