Dimplex SI5ME Ground Source Heat Pump

User Manual - Page 25

For SI5ME.

PDF File Manual, 56 pages, Download pdf file

Loading ...
Loading ...
Loading ...
www.dimplex.de 452232.66.13 · FD 9603 EN-11
English
SI 5ME - SI 14ME
12 Device Information
1 Type and order code
SI 5ME SI 7ME SI 9ME SI 11ME SI 14ME
2Design
2.1 Degree of protection according to EN 60 529 IP 20 IP 20 IP 20 IP 20 IP 20
2.2 Installation Location Indoors Indoors Indoors Indoors Indoors
3 Performance data
3.1 Operating temperature limits:
Heating water flow °C Up to 58 Up to 58 Up to 58 Up to 58 Up to 58
Brine (heat source) °C -5 to +25 -5 to +25 -5 to +25 -5 to +25 -5 to +25
Antifreeze
Mono-ethyl-
ene glycol
Mono-ethyl-
ene glycol
Mono-ethyl-
ene glycol
Mono-ethyl-
ene glycol
Mono-ethyl-
ene glycol
Minimum brine concentration (-13 °C freezing temperature) 25% 25% 25% 25% 25%
3.2 Temperature spread of heating water (flow/return flow)
at B0 / W35 K
5.05.05.05.05.0
3.3 Heat output / COP at B0 / W35
1
kW / ---
1. These data indicate the size and capacity of the system according to EN 14511 (5K at A7). For an analysis of the economic and energy efficiency of the system, the bivalence
point and the regulation, should also be taken into consideration. These specifications can only be achieved with clean heat exchangers. Information on the maintenance, start-up
and operation can be found in the respective sections of the installation and operating instructions.
The specified values have the following meaning, e.g. B10/W55: External air temperature 10 °C and heating water flow temperature 55 °C.
4,9 / 3,8 6,3 / 3,7 8,9 / 3,8 10,8 / 3,9 15,3 / 3,9
at B0 / W45
1
kW / ---
4,6 / 2,8 5,7 / 2,9 8,5 / 2,8 10,0 / 2,9 15,0 / 3,2
3.4 Sound power level to DIN 12102 dB(A) 54 55 56 56 56
3.5 Heating water flow with an internal pressure differential of m³/h / Pa 0,85 / 6500 1,1 / 10000 1,5 / 9200 1,9 / 15000 2,7 / 20500
3.6 Brine throughput with an internal pressure
differential (heat source) of m³/h / Pa
1,2 / 16000 1,7 / 29500 2,0 / 20000 2,5 / 18000 3,6 / 20900
3.7 Refrigerant; total filling weight type / kg R407C / 1.2 R407C / 1.4 R407C / 1.7 R407C / 1.9 R407C / 2.2
3.8 Lubricant; total filling weight type / litres
Polyolester
(POE) / 1.0
Polyolester
(POE) / 1.0
Polyolester
(POE) / 1.1
Polyolester
(POE) / 1.4
Polyolester
(POE) / 1.9
4 Dimensions, connections and weight
4.1 Device dimensions without connections
2
H x W x L mm
2. Note that additional space is required for pipe connections, operation and maintenance.
805 650
462
805 650
462
805 650
462
805 650
462
805 650
462
4.2 Device connections to heating system Inch
G 1¼" exter-
nal
G 1¼" exter-
nal
G 1¼" exter-
nal
G 1¼" exter-
nal
G 1¼" exter-
nal
4.3 Device connections to heat source Inch
G 1¼"
external
G 1¼"
external
G 1¼"
external
G 1¼"
external
G 1¼"
external
4.4 Weight of the transportable unit(s) incl. packing kg 109 111 118 122 130
5 Electrical Connection
5.1 Nominal voltage; fuse protection V / A 230 / 16 230 / 16 230 / 20 230 / 25 230 / 32
5.2 Nominal power consumption
1
B0 W35 kW
1,30 1,58 2,22 2,69 3,83
5.3 Starting current with soft starter A 24 26 38 38 45
5.4 Nominal current B0 W35 / cos A / --- 7,1 / 0,8 8,6 / 0,8 12,1 / 0,8 14,6 / 0,8 20,8 / 0,8
6 Complies with the European safety regulations
3
3. See CE declaration of conformity
3333
7 Additional model features
7.1 Water in device protected against freezing
4
4. The heat circulating pump and the heat pump manager must always be ready for operation.
No No No No No
7.2 Performance levels 1 1 1 1 1
7.3 Controller internal/external Internal Internal Internal Internal Internal
7.4 Max. operating overpressure (heat source/heat sink) bar 3,0 3,0 3,0 3,0 3,0
Loading ...