Myers MSCI75V10-R 3/4 HP Cast Iron Sump Pump

INSTALLATION AND OPERATION MANUAL - Page 6

For MSCI75V10-R. Also, The document are for others Myers models: MSCI50V10-R

PDF File Manual, 28 pages, Read Online | Download pdf file

MSCI75V10-R photo
Loading ...
Loading ...
Loading ...
6
MY1016-R (06-23-20)
PERFORMANCE & SPECIFICATIONS
SPECIFICATIONS
Power supply required..................................................................................................................115V, 60 HZ., 15 Amp Circuit
Liquid temp. range.......................................................................................................................32°F to 70°F(0°-21°C)
Individual branch circuit eequired (min.).......................................................................................15 Amps
Discharge.....................................................................................................................................1-1/2” Female NPT
NOTE:
Do not reduce size of discharge pipe or hose below 1-1/4” diameter. If discharge is too small, pump will overheat and fail prematurely.
ELECTRICAL & SWITCH SPECIFICATIONS
SERIES HP
MOTOR FULL
LOAD AMPS
INDIVIDUAL
BRANCH CIRCUIT
REQ. (AMPS)
AUTOMATIC SWITCH
TYPE
SWITCH SETTING IN INCHES
WATER LEVEL FOR:
ON OFF
MSCI50V10-R 1/3 6.9 15A 115VAC Vertical Switch 7 1/2" 3"
MSCI75V10-R 1/2 7.7 15A 115VAC Vertical Switch 7 1/2" 3"
PERFORMANCE
GPH (LPH) at total feet (m) of lift
SERIES HP
0'
(0.0m)
5'
(1.5m)
10'
(3m)
15'
(4.6M)
20'
(6.1M)
25'
(6.1M)
NO FLOW AT
HEIGHT SHOWN
BELOW IN FEET
(METERS)
Capacity Gallons(L)/Hour
MSCI50V10-R 1/3
4800
(18170)
4320
(16353)
3660
(13855)
2640
(9993)
1020
(3861)
0 (0) 22 (7)
MSCI75V10-R 1/2
5820
(22031)
5220
(19760)
4560
(17260)
3780
(14309)
1780
(6738)
0(0) 29 (8.84)
Loading ...
Loading ...
Loading ...