MY1016-R (06-23-20)
RENDIMIENTO Y ESPECIFICACIONES
ESPECIFICACIONES
Fuente de alimentación requerida ................................................................................................... 115V, 60Hz, circuito de 15A
Rango de temperatura de líquido ..................................................................................................... 32 °F a 70 °F (0 °C a 21 °C)
Circuito de derivación individual requerido (mín.) ............................................................................. 15A
Descarga ........................................................................................................................................1-1/2” NPT hembra
NOTA:
No reduzca el tamaño del tubo o la manguera de descarga a menos de 1-1/4” de diámetro. Si la descarga es demasiado pequeña, la bomba
serecalentará y comenzará a tener fallas prematuras.
ESPECIFICACIONES DE ELECTRICIDAD E INTERRUPTORES
SERIE HP
CARGA TOTAL
DEL MOTOR
(AMPERIOS)
REQ. CIRCUITO
DE DERIVACIÓN
INDIVIDUAL
(AMPS)
TIPO DE INTERRUPTOR
AUTOMÁTICO
AJUSTES DEL INTERRUPTOR
ENNIVEL DE AGUA EN PULGADAS
PARA:
ENCENDIDO APAGADO
MSCI50V10-R 1/3 6.9 15A 115VCA Interruptor vertical 7 1/2" 3"
MSCI75V10-R 1/2 7.7 15A 115VCA Interruptor vertical 7 1/2" 3"
RENDIMIENTO
GPH (LPH) al total de pies (m) de elevación
SERIE HP
0'
(0.0m)
5'
(1.5m)
10'
(3m)
15'
(4.6M)
20'
(6.1M)
25'
(6.1M)
SE MUESTRA
LAFALTA DE FLUJO
A LAS ALTURAS
SIGUIENTES
ENPIES (METROS)
Capacidad en galones (L)/Hora
MSCI50V10-R 1/3
4800
(18170)
4320
(16353)
3660
(13855)
2640
(9993)
1020
(3861)
0 (0) 22 (7)
MSCI75V10-R 1/2
5820
(22031)
5220
(19760)
4560
(17260)
3780
(14309)
1780
(6738)
0(0) 29 (8.84)
Loading ...
Loading ...