User Manual Durablow TR2001 Gas Fireplace On/Off Remote Control Kit

Documents for Durablow TR2001

The following documents are available:
User Manual Specification Photos
TR2001 photo

User Manual

For TR2001.

TROUBLESHOOTING
For all Durablow fireplace remote control kits
OBSERVED
PROBLEM
POSSIBLE
CAUSE
REMEDY
Fireplace fire shuts off
in use.
(If equips ODS - Oxygen
Depletion Sensing)
1. No enough fresh air in room, the ODS
pilot shuts off the entire system.
2. ODS/pilot is partially clogged.
1. Open window and/or door for
ventilation.
2. Clean ODS/pilot.
Fireplace fire shuts off
in use.
1. Timer is up or schedule is triggered.
2. Receiver box is overheated.
3. *Set Temperature is reached. (if use a
Thermostat remote control model)
4. Power outage or battery low.
1. Check Timer or Schedule settings.
2. Relocate receiver away from heat.
3. *Check thermostat setting.
4. Check power source, power cord or
replace batteries.
Main fire does not light
after pilot is lit.
1. Inlet gas pressure is too low.
2. Thermopile leads disconnected or
improperly connected.
3. Thermopile damaged.
4. Remote control receiver box wires
disconnected or improperly connected.
5. Pilot fire is OFF accidentally or clogged.
1. Contact local nature gas company.
2. Reconnect thermopile leads.
3. Replace thermopile.
4. Reconnect the wires to TH, TH/TP
terminals of Millivolt valve properly.
5. Ignite pilot fire again, or clean pilot.
No voltage output from
Durablow remote
control receiver box
when control is ON.
The remote control receiver box does NOT
output a micro-volt voltage by itself (for no
danger of gas leakage). It passes or
no-pass the voltage that is generated by
thermopile (heated by pilot fire).
1. Turn ON the pilot fire.
2. Reconnect thermopile leads.
3. Replace thermopile.
4. Switch the receiver box to
“REMOTE” mode.
5. Allow more time to have thermopile
heated to generate voltage.
Durablow remote
control does not
function.
1. No battery or battery is low.
2. Weak signal. Receiver is obstructed or
covered by metal objects / housing.
3. Out of use distance.
4. Weak Wi-Fi (smart home remote only)
5. Defective device.
1. Replace batteries in transmitter and
receiver.
2. Relocate receiver.
3. Relocate receiver and transmitter.
4. Relocate receiver or Wi-Fi router.
5. Contact seller for replacement.
Fireplace fire is ON and
OFF too often or too
slow. (Thermostat remote
control model only)
1. Temperature “SWING” setting is too
small or too big.
1. Find “SWING” setting on
transmitter handset, or Smart Life APP
(Smart Home remote control models),
and reselect appropriate Swing levels:
2°F(1°C), 4°F(2°C), 6°F(3°C)
Pilot fire can NOT be
ignited by Durablow
remote control.
Durablow remote control is not a ignitor, it
acts like a main gas fire ON/OFF switch.
Not used for igniting pilot fire or main fire.
1. Ignitor is damaged or battery low.
2. Millivolt valve is not at INGITE mode.
3. Fireplace IPI control is not working.
1. Ignite pilot fire by built-in fireplace
spark ignitor, or manual torch lighter.
2. Turn/press knob on Millivolt valve to
release gas for pilot fire.
3. Contact original fireplace maker.
(2020.11)

Specifications

Durablow TR2001 Questions and Answers


#1 Will this work with Vermont Castings Gas fireplace? also does this function as just a on/off function or can I input a room temperature to set.

For this remote control kit, it works with any fireplaces / fire pits which have Millivolt valves or valves having TH, TH/TP terminals (signal use).
OR, replacing your wall switch (or any types of ON/OFF, thermostat switches), or add this device by connecting it in series with existing switch. Manual cut and connection may be required. Installing by qualified technician only.
Please check your fireplace or fire pit user manual ( or original maker) for more valve information, or google with keywords " fireplace model + manual".
For your reference, please find the demo illustration of Millivolt valve wiring connection in listing images.
ATTENTION: Fireplace won't be turned on if either your Pilot Fire or Thermopile is not working in your fireplace.

#2 I replaced my inputs from the wall switch but the device doesn't start the flame. How do I know if I need a transformer for my electronic module?

1.For this remote control kit, it works with any fireplaces / fire pits which have Millivolt valves or valves having TH, TH/TP terminals (signal use).
OR, replacing your wall switch (or any types of ON/OFF, thermostat switches), or add this device by connecting it in series with existing switch. Manual cut and connection may be required. Installing by qualified technician only.

2.Please check your fireplace or fire pit user manual ( or original maker) for more valve information, or google with keywords " fireplace model + manual".
For your reference, please find the demo illustration of Millivolt valve wiring connection in listing images.

See other models: TR1004 TR1003 TR1001