Press + to select more weekdays.
The selected weekdays are marked with a triangle displayed
permanently. The days Monday to Friday are selected on the screen
at the top. Deselect weekdays with the - key.
Press the ENTER key. The settings are saved. COPY ashes three
times. Setting is complete.
Frost Protection
In MANUAL OFF operating mode and Auto operating mode (time block
OFF), frost protection takes place. If the room temperature is 5° C or
less, the heating device is switched on automatically.
Adaptive Start
This function guarantees that, in automatic mode (week program), the
set room temperature is achieved exactly at the start of the switch-
on time.
Example:
In the timer menu, a set room temperature of 22°C is specied. The
current room temperature is 17° C. The heating device switches on early
so that the specied room temperature of 22° C is reached by 07:00.
Use the MODE key to select the operating mode AUTO
Press and hold the + and - keys for three seconds
ECO appears
Activate / deactivate the function with the +/- keys:
ON = Adaptive start activated
OFF = Adaptive start deactivated
Press the ENTER key. Setting is saved.
Options
Key Lock
This function can be used to lock the operating elements
Press and hold the ENTER key and MODE key for one second
The LOCKED key symbol appears in the display.
To unlock, press and hold the ENTER key and the MODE key at
the same time again
NOTE: No settings can be made if the key lock is activated
Use the +/- keys to set the weekday
Setting time block ON
press the ENTER key. P1 (period 1) and ON apprears. The hours
display ashes
Use the +/- keys to set the hours. Press the ENTER key. The
minutes display ahses.
Use the +/- to set minutes (in 10 minute increments)
Setting time block OFF
Press the ENTER key. P1 (program 1) and OFF appears. The hours
display ashes.
Use the +/- keys to set the hours. Press the ENTER key. The
minutes display ashes.
Use the +/- keys to set the minutes
Temperature setting
Press the ENTER key. Temperature setting appears
Use the +/- keys to set the temperature.
Press the ENTER key. P2 (program 2) and ON appears. The hours
display ashes.
The programs P2, P3 and P4 can be set in the same way.
NOTE: To exit the program early, press the PROG key
Copying Programs
To copy the newly set programs P1 - P4 to other days, proceed as follows.
After carrying out the Temperature Setting, press and hold the
ENTER key until COPY appears.
Turbo Fan
The turbo fan can be used to circulate the heat around the room to
help it reach the desired temperature more quickly. On this model with
the ON/OFF switch at ON position and the turbo switch in the OFF
position, there will be 2kW output from the convector (NOTE: 2kW is
only possible with turbo OFF). To activate 3kW output, turn ON the
turbo switch which will combine the 2kW setting with a 1kW fan boost
setting to give a total of 3kW with fan boost.