Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: [email protected] | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
Indoor Location
Installation distances may vary by local code. It is the installer’s responsibility to verify
installation requirements.
Make sure before installation that the gas type you will use is the same type on the data plate.
The water heater unit should be installed by professionals. Improper installation may cause
failure or dangerous conditions such as gas leaking or explosion.
Water Heater cannot be installed in an UN-VENTED bathroom, bedroom, basement, living room,
closet, outdoor, stairway or an exit area. If installed in an exit area, it must be at least 16.5 ft. or
more away from the exit.
Vent pipe should extend from the wall at least 2”. The terminal must be at least 1.64 ft. away
from obstruction, and must be well vented.
Vent pipe should slope 3° downward, to avoid condensing water and protect from rain entering.
Vent pipe should avoid direct, strong wind because the downdraft will cause malfunction.
The unit should be installed far from any blockage, and with plenty of enough space for
installation and maintenance. Adequate clearances for servicing must be provided.
The unit should not be installed in the same room with a gas stove .
When determining the oor clearance, a clearance of 6 inches must be maintained between the
vent pipe and combustible material. A side wall clearance of 6 inches and a top clearance of 12
inches must be maintained.
A maximum of 32 feet of vent pipe may be used provided there is only one 90° elbow in the
system. If additional elbows are required: two elbows can be used with 27 feet, and three
elbows can be used with 22 feet of vent pipe.
A 90° elbow is equivalent to 5 feet of straight pipe. A 45° elbow is equivalent to 2 feet 6 inches
of straight pipe .
The vent pipe should be installed with a ame retardant wall thimble. Owner must refer to vent
manufacturer’s instructions and specications.
The power socket connecting the water heater should be grounded properly with a GFCI circuit
protector.
The water heater should not be located in an area where leakage of the heat exchanger or
connections will result in damage to the area adjacent to it or to lower oors of the structure.
When such areas cannot be avoided it is recommended that a suitable catch pan, adequately
drained, must be installed under the water heater. The pan must not restrict combustion
airow.
The water heater should be installed as close as practical to the vent termination to minimize
vent length and the number of elbows required for venting.
A gas red water heater or any other appliance should not be installed in a space where liquids
which give off ammable vapors are to be used or stored. Such liquids include gasoline, LP gas
(butane or propane), paint or adhesives and their thinners, solvents or removers.
Installing the water heater