27
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: [email protected] | Address: 315 - A Industrial RD Summerville, SC 29483
PLEASE NOTE: THIS MANUAL IS SUBJECT TO CHANGE AT ANYTIME, TO ENSURE THIS MANUAL IS UP TO DATE PLEASE VISIT OUR HELPDESK AT WWW.ECCOTEMP.COM
FOR ALL OF OUR PRODUCT MANUALS.
PLEASE NOTE: THIS MODEL IS FOR INDOOR PERMANENT INSTALLATIONS ONLY.
CLEANING THE WATER HEATER AND REMOTE CONTROL(S):
• Make sure the unit is OFF and the electrical power supply has been disconnected.
DO NOT scrub the appliance with a brush.
• Use only mild soapy water, other cleaners may damage the surface of the water heater.
DO NOT remove any label including the rating plate while cleaning or servicing.
DO NOT splash water on the remote controls when cleaning.
NOTICE: DO NOT block or obstruct the air intake opening located at the lower left corner of the water heater. A
minimum of 12” is required between this combustion air inlet opening and any obstruction.
Venting System Inspection
The venting system should be inspected annually to ensure all of the vent sections are secure and airtight.
It is recommended that qualied service personnel familiar with Category III venting inspect the venting system.
Check vent connection joint sections with a solution of soapy water to assure airtightness while the unit is
operating. Bubbles around a joint connection indicates a seal leak. Refer to page 14 for vent sealing instructions.
DO NOT operate the unit if vent system shows signs of leaking exhaust.
Check to make sure that the Air Intake and the vent terminal have not been blocked or contain debris.
Vacation and Extended Shut-Down
If the water heater is to remain idle for an extended period of time, the power and water to the appliance should
be turned off.
The water heater and piping should be drained if they might be subjected to freezing temperatures.
After a long shut-down period, the water heater’s operation and controls should be checked by qualied service
personnel.
HOW TO CLEAN THE WATER FILTER:
1. Make sure the unit is OFF and the electrical power supply has
been disconnected.
2. Turn the water supply OFF to the heater.
3. Unscrew the water lter, and slide the lter out.
4. DO NOT tap the lter as it may deform and/or damage the lter.
5. To remove severe dust, use a soft brush and wash with running
water.
6. Return the lter to the water heater and screw in the lter.
7. Turn the electrical power supply and cold water supply ON to the
water heater
Housekeeping continued...
Not Equipped with Anti-Freezing Protection
Draining Procedure
When the temperature falls below 32°F, water in your plumbing system or water heater can turn to ice and then
expand causing damage to the water heater. This damage is not covered under your manufacturer’s warranty. If
these conditions are anticipated, please drain the water heater as follows to help but not guarantee from freezing:
1. Shut off the main gas valve and power
2. Shut off the inlet water valve
3. Open all faucets
4. Take off the drain valve, and allow water to drain for 3 minutes or until the unit is empty.
5. Making sure all water is out, replace the drain valve, and shut off the faucets.