Loading ...
Product Support: Eccotemp.com/help-desk Shop Online: Eccotemp.com/products Store Locater: Eccotemp.com/locater
Phone: 866-356-1992 | Email: [email protected] | Address: 315 - A Industrial RD Summerville, SC 29483
WARNING: If the information in these instructions is not followed exactly,
a re or explosion may result causing property damage, personal injury
or death.
Do not store or use gasoline or other ammable vapors and liquids in
the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your
building.
Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the re department.
Installation and service must be performed by a qualied installer
service agency or the gas supplier.
Eccotemp Systems, LLC
315-A Industrial Road
Summerville, SC 29483
866-356-1992
AUTOMATIC INSTANTANEOUS WATER HEATER
MODEL #:
i12-NG
SERIAL #:
TYPE GAS:
NATURAL GAS
ONLY Minimum Inlet Gas Pressure:
Minimum Input Rang (Btu per hour):
Maximum Input Rang (Btu per hour):
Voltage:
120 Volts
Maximum Inlet Gas Pressure:
Frequency:
60 Hz
Manifold Pressure:
Amps:
Less than 12 Amperes
Maximum Working Pressure:
Recovery
Rang:
SUITABLE FOR WATER (POTABLE) HEATING ONLY
As used in this standard, the quanty of water obtained by mulplying the
manufacturer's input rang in Btu per hour by the thermal efficiency and dividing
the product by 825 Btu per gallon. This is based on a 100°F temperature rise, and
a nominal specific heat for water of 8.25 Btu per gallon per degree F.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance
This appliance must be installed in accordance
with local codes or, in the absence of local
codes, the Naonal Fuel Gas Code, Natural Gas
and Propane Installaon Code
80,000
20,000
4” w.c
(1Kpa)
10.5'' w.c
(2.61Kpa)
3.05'' w.c
(0.76Kpa)
150 psi
The temperature and pressure relief valve provided by the manufacturer shall be installed at the
me of installaon of the heater in the locaon specified by the manufacturer. Local codes shall
govern installaon of relief devices. For safe operaon of the water heater, the relief valve must
not be removed or plugged.
INDOOR USE ONLY
The unit must be installed on a fire retardant area, and must be away from all combusble
materials. Clearance should be 1.75 to the le and right side of combusble materials, and
6.75  to the front.
Open on three sides and an overhead clearance of 36”
Not recommended in excess of 3,800 . above sea level.
Eccotemp Systems, LLC
315-A Industrial Road
Summerville, SC 29483
866-356-1992
AUTOMATIC INSTANTANEOUS WATER HEATER
MODEL #:
i12-LP
SERIAL #:
TYPE GAS:
LIQUID PROPANE
ONLY Minimum Inlet Gas Pressure:
Minimum Input Rang (Btu per hour):
Maximum Input Rang (Btu per hour):
Voltage:
120 Volts
Maximum Inlet Gas Pressure:
Frequency:
60 Hz
Manifold Pressure:
Amps:
Less than 12 Amperes
Maximum Working Pressure:
Recovery
Rang:
SUITABLE FOR WATER (POTABLE) HEATING ONLY
As used in this standard, the quanty of water obtained by mulplying the
manufacturer's input rang in Btu per hour by the thermal efficiency and dividing
the product by 825 Btu per gallon. This is based on a 100°F temperature rise, and
a nominal specific heat for water of 8.25 Btu per gallon per degree F.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance
This appliance must be installed in accordance
with local codes or, in the absence of local
codes, the Naonal Fuel Gas Code, Natural Gas
and Propane Installaon Code
80,000
20,000
9'' w.c
(2.24 Kpa)
13'' w.c
(3.23Kpa)
4.93'' w.c
(1.22Kpa)
150 psi
The temperature and pressure relief valve provided by the manufacturer shall be installed at the
me of installaon of the heater in the locaon specified by the manufacturer. Local codes shall
govern installaon of relief devices. For safe operaon of the water heater, the relief valve must
not be removed or plugged.
INDOOR USE ONLY
The unit must be installed on a fire retardant area, and must be away from all combusble
materials. Clearance should be 1.75 to the le and right side of combusble materials, and
6.75  to the front.
Open on three sides and an overhead clearance of 36”
Not recommended in excess of 3,800 . above sea level.
Loading ...
Loading ...
Loading ...