DFT Installation Instructions
Page: 14
Prepare Uncoupling Membrane for Cable Insertion
Before installing the cable in the uncoupling membrane channels, ensure that all the surfaces on which
the membrane will lie are free of any sharp edges, debris or other restrictions that may cut or otherwise
damage the heating cable or membrane�
Once the mortar has dried, determine which cable spacing you want to select, see Table 1� When you are
laying your cable out, ensure that the cable is at minimum of 1" (25mm) from the membrane edge and
no further than 6" (150mm) from the wall� Do not increase cable spacing more than 3-3/4" (90mm), and
that there is a minimum of 1�5" (38mm) spacing between cable runs�
Table 1
Cable Spacing Power Output Number of tabs per run
Standard 12 Watts/sqft
3 tabs (3�6")
Alternating 15 Watts/sqft 2–3 tabs repeat (3�0")
Note: Cable run spacing is for membranes with a tab spacing of 1�2" (30mm) +/- 0�05� For membranes
with dierent tab spacing, adjust the spacing by the percent dierence�
16
EasyHeat.TechnicalServices@Emerson.com
Add contact info and company name and such
Standard
12 Watts/sqft
(3.6")
Alternating
15 Watts/sqft
(3.0")
Cable run spacing is for membranes with a tab spacing of 1.2” (30mm) +/- 0.05. For membranes with different tab spacing, adjust
the spacing by the percent difference.
Figure 101 Number of tabs per run
Lace Cable Through Uncoupling Membrane
1. Inserting the cable into the pre-made channels and follow the appropriate spacing as
mentioned in 2.3B. Ensure that the cable is properly set inside the membrane so that the
surface of the membrane stays level (i.e. no cable is popping out of the membrane).
2. If any adjustment in the cable spacing is required, carefully pull out heating cable from the
channels and reposition.
Warranty
WARM TILES® LIMITED WARRANTY
AND LIABILITY
EasyHeat® warrants to the original purchaser only, that if there are any defects in material or workmanship in any Warm Tiles mat or cable during the first fifteen (15) years after
the date of its purchase, we will refund the purchase price paid for the mat or cable, not including any labor or other installation costs.
Figure 21
Lace Cable Through Uncoupling Membrane
1� Inserting the cable into the pre-made channels and follow the appropriate spacing as mentioned
in Table 1� Ensure that the cable is properly set inside the membrane so that the surface of the
membrane stays level (i�e�, no cable is popping out of the membrane)�
2� If any adjustment in the cable spacing is required, carefully pull out heating cable from the
channels and reposition�