Fortypicalundercounterinstallationofanelectricbuilt-inovenseeFigurebelow.
Onlycertaincooktopmodelsmaybeinstalled
overcertainbuilt-inelectricovenmodels.
Approvedcooktopsandbuilt-inovensarelisted
bytheMFGIDnumberandproductcode(seethe
insertsheetincludedintheliteraturepackagea[
cooktopinstallationinstructionsfordimensions).
Toreducetheriskof
personalinjuryand
tippingof thewall
oven,thewall oven
mustbesecuredto
thecabinet(s)by
mountingbrackets,
208/240Voltjunctionbox
forbuilt-inoven.
Models790-4511"
and790-4521"are
NOTapprovedto be
combinedwith awall
ovenin CANADA,
Approx. 3"
(7.5cm)
Cut an opening in wood base minimum 4" x 4"
(10.2 X 10.2cm), 2" (5cm) from left side filler
panel, to route armored cable to junction box.
Note 1 4" x 4" (10.2cm X 10.2cm) opening to
route armored cable from cooktop to junction
box.
Approx. 3" 208/240Volt
(7.5cm) junction box
for cooktop
Cabinet side filler
panels are necessary to
isolate the unit from
adjoining cabinets.
Cabinet side filler
height should allow for
of approved
cooktop models
36" Min.
(91.4cm) Min.
Unit will
overlap
(minimum)
edges by 1"
(2.5cm) 41/2" (11.5cm)
Max.*
Use 3/4" (1.gcm) plywood,
installed on two runners,
flush with toe plate.
Base must be capable of
supporting 150 pounds
(68kg) for 27" models and
200 pounds (90kg) for 30"
models.
* If no cooktop is installed directly
over the oven unit, 5" (12.7cm)
maximum is allowed above the
floor.
27" (68.6cm) 247/8'' (63.2cm) Min. 23Y2" (59.7cm) Min. 27¼" (69.2cm) Min.
Wall Oven 25¼" (64.1cm) Max. 28¼" (71.8cm) Max.
30" (76.2cm) 281/2'' (72.4cm) Min. 23Y2" (59.7cm) Min. 27¼" (69.2cm) Min.
Wall Oven 29" (73.7cm) Max. 28¼" (71.8cm) Max.
Figure 9- TYPICAL UNDER COUNTER INSTALLATION OF A SINGLE ELECTRICBUILT-IN OVEN