English - 31
OPERATING
Removing any residual matter inside the
water supply line after installing the water
lter.
1. Turn ON the main water supply and supply
water from water supply line.
2. Run water through the dispenser until the water
runs clear (approx. 6 to 7 minutes).
This will clean the water supply system and
remove air from the lines.
3. Additional fl ushing may be required in some
households.
4. Open the Refrigerator door and make sure there
are no water leaks coming from the water fi lter.
Be sure to fl ush the dispenser thoroughly,
otherwise water may drip from the
dispenser.
This means that there is still air in the line.
Reverse Osmosis Water Supply
IMPORTANT:
The pressure of the water supply coming out of a
reverse osmosis system going to the water inlet
valve of the refrigerator needs to be between 241
and 827kPa.
If a reverse osmosis water fi ltration system is
connected to your cold water supply, the water
pressure to the reverse osmosis system needs to
be a minimum of 276 to 414kPa.
If the water pressure to the reverse osmosis system
is less than 276 to 414kPa:
Check to see whether the sediment fi lter in the
reverse osmosis system is blocked.
Replace the fi lter if necessary.
Allow the storage tank on the reverse osmosis
system to refi ll after heavy usage.
If your refrigerator has a water fi lter, it may
further reduce the water pressure when used
in conjunction with a reverse osmosis system.
Remove the water fi lter.
If you have questions about your water pressure,
call a licensed, qualifi ed plumber.
DA68-03194H (EN)-04.indd 31DA68-03194H (EN)-04.indd 31 2015. 6. 1.  1:042015. 6. 1.  1:04