Installation Instructions
ELECTRICAL CONNECTIONS
Electrical Requirements
You must use a 120-volt, 60 Hertz, properly grounded
dedicated circuit protected by a 15-amp or 20-amp
circuit breaker or time delay fuse.
Extension Cord Cautions
Because of potential safety hazards associated with
certain conditions, we strongly recommend against the
use of an extension cord. However, if you still elect to use
an extension cord, it is absolutely necessary that it be a
UL-listed, 3-wire grounding-type appliance extension
cord and that the current carrying rating of the cord in
amperes be equivalent to, or greater than, the circuit
rating.
Grounding
IMPORTANT—(Please read carefully)
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED.
The power cord of this appliance is equipped with
a three-prong (grounding) plug which mates with
a standard three-prong grounding wall receptacle to
minimize the possibility of electric shock hazard from
this appliance.
The customer should have the wall receptacle and circuit
checked by a qualified electrician to make sure the
receptacle is properly grounded.
Where a standard two-prong wall receptacle is
encountered, it is the personal responsibility and
obligation of the customer to have it replaced with
a properly grounded three-prong wall receptacle.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE
THE THIRD (GROUND) PRONG FROM THE POWER CORD.
A word about GFCI’s – GFCI’s are not required or
recommended for gas range receptacles.
Ground Fault Circuit Interrupters (GFCI’s) are devices that
sense leakage of current in a circuit and automatically
switch off power when a threshold leakage level is
detected. These devices must be manually reset by the
consumer. The National Electrical Code requires the use of
GFCI’s in kitchen receptacles installed to serve countertop
surfaces. Performance of the range will not be affected if
operated on a GFCI-protected circuit but occasional
nuisance tripping of the GFCI breaker is possible.
Preferred
Method
Ensure proper ground
exists before use
ELECTRICAL CONNECTIONS (CONT.)
3
A. Usage Situations where Appliance Power Cord will be
Disconnected Infrequently.
An adapter may be used only on a 15-amp circuit. Do not
use an adapter on a 20-amp circuit. Where local codes
permit, a TEMPORARY CONNECTION may be made to a
properly grounded two-prong wall receptacle by the use
of a UL-listed adapter, available at most hardware stores.
The larger slot in the adapter must be aligned with the
larger slot in the wall receptacle to provide proper polarity
in the connection of the power cord.
When disconnecting the power cord from the adapter,
always hold the adapter with one hand. If this is not done,
the adapter ground terminal is very likely to break with
repeated use. Should this happen, DO NOT USE the
appliance until a proper ground has again been
established.
CAUTION: Attaching the adapter
ground terminal to the wall receptacle cover
screw does not ground the appliance unless
the cover screw is metal, and not insulated,
and the wall receptacle is grounded through
the house wiring. The customer should have
the circuit checked by a qualified electrician to
make sure the receptacle is properly grounded.
Temporary Method
Ensure proper ground
and firm connection
before use
(Adapter plugs not permitted in Canada)
Align large
prongs/slots
3