En-7
● OPERATING INSTRUCTIONS ●
Air outlet and Fan (before cleaning, make sure that the fan is stopped)
CLEANING
1
Turn the horizontal vanes down-
ward. Then, remove the upper
vane as shown in ➀and .
Repeat ➀and ➁for the lower vane.
2
Swing out the two vertical vanes
one by one.
4
Put the vertical vanes back to their
original positions correctly one by
one, into their respective guide.
Push the vanes until they click into place.
5
Install the horizontal vane by
following the removal procedure
in reverse.
If the horizontal vane is not installed cor-
rectly, all LED lamps blink when power is
turned on.
Note:
Do not apply excessive force to the fan or fan
guard.
Lower vane
Upper vane
Unlock
Guide
Important
Clean the lters regularly for best performance and to
reduce power consumption.
Dirty lters cause condensation in the air conditioner
which will contribute to the growth of fungi such as
mold. It is therefore recommended to clean air lters
every 2 weeks.
Instructions:
Switch off the power supply or turn off the breaker before cleaning.
Be careful not to touch the metal parts with your hands.
Do not use benzine, thinner, polishing powder, or insecticide.
Use only diluted mild detergents.
Do not expose parts to direct sunlight, heat, or re to dry.
Do not use water hotter than 50°C.
Front panel
1. Lift the front panel until a “click” is heard.
2. Hold the hinges and pull to remove as shown in the above illustration.
Wipe with a soft dry cloth or rinse it with water.
Do not soak it in water for more than two hours.
Dry it well in shade.
3. Install the front panel by following the removal pro
-
cedure
in reverse. Close the front panel securely
and press the positions indicated by the arrows.
Hole
Hinge
Air lter (Catechin air lter)
Clean every 2 weeks
Remove dirt by a vacuum cleaner, or rinse with water.
Dry it well in shade.
Air cleaning lter
(Anti-Allergy Enzyme Filter, option)
Back side of air lter
Every 3 months:
Remove dirt by a vacuum cleaner.
When dirt cannot be removed by
vacuum cleaning:
Soak the lter and its frame in luke-
warm water before rinsing it.
After washing, dry it well in shade.
Install all tabs of air lter.
Every year:
Replace it with a new air cleaning lter for best performance.
Parts Number
MAC-408FT-E
What is “Catechin air lter” ?
Catechin is a bioavonoid that is found in green tea that has both antivi-
ral and antioxidant qualities. In addition to these benets, Catechin also
offers excellent deodorizing characteristics. Catechin air lter uses this
compound
to not only improve air quality but also prevent the spread of
bacteria and viruses in the room.
Pull to remove from the air lter
3
Clean the air outlet and fan.
Wipe with a soft dry cloth.
Clean the fan.
Use the QUICK CLEAN KIT (option).
Parts Number MAC-093SS-E
Refer to
the instructions described in the
QUICK CLEAN KIT for details.
Heat exchanger
Wear gloves to protect your hands.
Use the QUICK CLEAN KIT
(option).
Parts Number MAC-093SS-E
Refer to
the instructions described in
the QUICK CLEAN KIT for details.
JG79A796H02_en.indd 7 2013/11/05 15:09:24