Manufacturer: Lianxiang (Zhongshan) Electronic Co., Ltd
Address: No. 5 Xinfu Road, Dongfeng Town, Zhongshan City, Guangdong Province, China
Tel/Fax: 0760-22636620
Humidifier
User Manual
(Image shown is for illustration purposes only. Actual product in package
may vary.)
Dear Customer: Please read the user manual carefully before use the
humidifier.
目录
Contents
Contents --01
Parts name --02
Working principle--03
How to use---04
Safety precautions---06
Clean & Maintenance --10
Troubleshooting---11
Specifications---12
Environmental list ----13
Warranty----14
Parts Name
顶盖-Top cover
出雾嘴- Mist nozzle
水箱-Water tank
消声器--Silencer
浮子--float
干簧管--Reed switch
顶针-- Probe
浮杆--Floating rod
浮杆支架--Floating rod bracket
机座--Humidifier Case
控制板--Control PCBA
风机--Fan
控制面板--Panel
按键--Buttons
杀菌灯支架-Germicidal lamp holder
杀菌灯--Germicidal lamp
PTC

PTC 压片--PTC tablet
雾化板--Atomizing plate
底板--Base
Special statement:
All contents of this manual have been carefully checked. In case of product technology or
software upgrade, a new version of the manual will be compiled. If the appearance color and
function of the product are modified, the actual product shall prevail.
Working principle
The humidifier uses 1.7 million times per second high frequency to mist
water into 1 to 5 micrometers ultra-fine particles, and diffuse the water mist
into the air through the fan to humidify the air.
How to use
1, Locate the humidifier horizontally on the desk, open water tank cover and
pull out water tank, pour in clean tap water or distilled water (Please
disconnect humidifier from power supply when add water), water do not
exceed the maximum water line.
2, Put the water tank on the base stable, close the water tank cover and plug
the humidifier to power supply, please make sure power supply meets the
rated power supply requirement.
3, When water level is too low, the humidifier will stop power supply and
stop working automatically, water indicator light (red) turns on. Please
unplug the humidifier and add water to the water tank.
4, Night light operation instructions: Press and hold the "time / light" button
for 3 seconds to turn on the light mode; the default is no night light when
turned on; the same reason for turning off: long press the "time / light"
button for 3 seconds to cancel.
Note: When the product is powered on, it defaults to the cold humidification
function. If you need the warm mist function, you need to click the warm fog
function key to enter the warm mist humidification function.
Functions:
H-580-A
1, Humidifier connect to power supply, humidifier standby, all lights off
2, Touch Power/Mist once to start the humidifier, mist light turns to blue
color, mist default to level 3 (High level) working, fan starts.
3, Touch Power/Mist , mist turns to level 2 (Mid level), mist light turns to red,
4, Touch Power/Mist, mist turns to levl 1 (Low level), mist light turns to

Purple
5, Touch Power/Mist, humidify turns to standby
6, When the humidifier is on, touch Sterilization once to start Sterilization,
Sterilization light turns on; touch again, Sterilization turns off, Sterilization
light off; Sterilization light off when standby or lack of water;
7, when the humidifier is on, touch heating once to turn on the heating,
heating light on; touch again, turn off heating and heating light off; heating
light off when standby or lack of water;
8, Automatic detection of water shortage, when water shortage alarms, Mist
light red light flashes and humidifier turns to standby after 10 seconds.
Functions
H-580-B
1, Humidifier connect to power supply, humidifier standby, all lights off
2, Touch Power to turn on, (Power indicator) light green, Mist default to level
3 (High level), fan starts
3, Touch Power again to turn off. If the the humidifier is at Mid level or Low
level, Touch Power to High level, touch again to turn off.
4, When the humidifier is on, touch Mid level once, mist turns to level 2(Mid
level), Mid level light on
5, When the humidifier is on, touch Low level once, mist turns to level 1 (Low
level), Low level light on
6, Automatic detection of water shortage, when water shortage alarms,
(Power indicator) light turns red, humidifier turns to standby after 10
seconds.
注意事项
Safety Precautions
1, Please do not plug or unplug with wet hand to avoid electric shock
2, Please do not disassemble, repair or modify the product by yourself
3, Please do not touch the atomizing plate when start the humidifier otherwise you might
have feeling of pain
4, Please do not scratch, damage or tie the power cable; nor clamp, reprocess or load heavy
objects on the cable otherwise might cause electric shock, short circuit and fire
5, Please do not replace the power cable by yourself. Please unplug if there is any abnormal and
contact manufacturer or sales service
6, If the power cable damaged, it has to be replaced by manufacturer, manufacturer’s repair
department or professional from other similar department
7, Do not separate water tank with base, do not touch water or other parts of base while
humidifier working
8, The humidifier is or indoor use only
9, Please cut off power during thunderstorm weather or long time no use.

10, Please do not overturn the humidifier while connecting to power or with water in the product
to avoid internal electronic components burnt down
11, Please keep the humidifier away for children’s touch, please not let children to use or operate
the humidifier to avoid accident
12, Please unplug when add water or clean
13, Power supply should meet rated voltage requirement, please do not use the humidifier and
contact vendor if the voltage do not meet requirement
14, Please leave the humidifier in room temperature for 30 minutes before use to avoid water
tank damage due to rapid temperature change
15, Please use the humidifier at a room temperature 5℃ to 40℃
16, Please place the humidifier horizontally, do not tilt
17, Please do locate the humidifier directly on wood floor to avoid wood floor damage from
moisture
18, Please use the humidifier 2 meters away from furniture and other Electric appliances from
moisture
19, Please place the humidifier away from heat source and avoid direct sunlight
20, Please do not add water over 40℃ to the water tank or sink to avoid humidifier damage
21, Please do not let water leak into the body of the product through wind outlet, please wipe
with clean cloth if any water on product body to avoid any damage
22, Please pour water out of water tank and sink is temperature below 0℃ to avoid icing
damage
23, Please do not put metal, chemical or detergent into water sink otherwise might cause poor
atomization
24, Please turn off the humidifier and unplug the power cable before pour water out of water
sink
25, Please turn off the humidifier and unplug the power cable before moving, cleaning or add
water. Do not move the humidifier when the humidifier is working.
26, Do not add water to mist nozzle or wind outlet.
27, Please avoid water leak into humidifier internal while cleaning
28, Do not disassemble the humidifier.
29, Do not put strong acid or strong alkaline liquid into the water tank (perfume, fragrance,
disinfection water, etc.), otherwise the sealing device will be corroded and water leakage or
product damage will occur; please note!
Tips: 温馨提示
1, About water in the base :
The humidifier uses ultrasonic atomizing plate to turn liquid water into mist. The water tank
is only a water filter and storage tool. It is normal if there is water in the base. Please do worry to
use the humidifier.
2, About mist adjustment:
If there is water around the machine during use, the humidity in the room is too high, please
adjust the mist amount appropriately.

Warning 警告
请勿进行改造 Please do not modify the humidifier. Do not disassemble or repair the product if
you are not professional otherwise might cause fire, electric shock or hurt accident. Please
contact our service central or authorized repair bureau.
请将本产品置于儿童 Please locate the humidifier out of children or disabled touch. Children or
disabled should use the humidifier under adult supervision.
产品出现故障时 Please stop use the humidifier, cut off power supply and contact service
central if any malfunction.
清洁前 Please unplug the humidifier before cleaning.
如果产品电源线 Please stop use the humidifier if any cable ,plug damage or humidifier flop on
the floor. Please replace the cable by professional if any cable damage.
弃置产品时 Please cut the cable before dispose the humidifier. Also dispose other parts might
harmful to children.
注意检查插头 Please check and make sure the plug and cable is in good condition to avoid
electric shock.
请确保所接电源 Please make sure the power supply is safe and the voltage meets the rated
voltage requirement
请勿将该产品浸入水中 Please soak the humidifier into water of other liquid, nor touch the
humidifier with wet hand otherwise might cause electric shock
本产品仅限于家用 The humidifier is for home use only, do not use the humidifier outdoor.
请勿使用电源线接近热源 Please keep the cable away from heat source
请勿将本产品置于高温的表面 Please do not place the humidifier on high temperature surface.
清洁与保养 Clean & Maintenance
清洗维护 Clean & Maintenance
1, Please clean the water tank, water sink and atomizing plate every week, please cut off power
supply before clean
2, Humidifier external cleaning: please wipe with clean soft wet cloth lower than temperature
40℃
3, Please do not use hare ware to clean to avoid parts damage.
4, Please do not clean with Chemical cleaner
5, Please change water in water tank often to keep the humidifier internal clean
6, Please keep humidifier internal dry is long time no use
换能器及机座除垢防范 Atomizing plate & base descaling method
1, Please cut off power and unplug before clean
2, Pour descaling agent into the base, add warm water around 60℃ to dissolve the agent, soak
for 5-10 minutes
3, Brush the surface of the atomizing plate with cleaning brush till scale removal
4, Clean the base at the same time, wash the base and atomizing plate surface with clean water

故障种类及常见问题 Troubleshooting
Problem Possible cause Solution
Light not on, no wind no mist Power not connected or power problem Reconnect to power
supply, contact service central if still not working
Light on, no wind no mist Water level too high in base Pour out some water from base
and restart
Low stream of mist Too much scale on atomizing plate or in the water Clean the
atomizing plate and change clean water
Water can not reach base water tank cover dirty or water tank not in position clean
water tank cover and locate water tan in position
Water level exceed maximum level Pour some water out
of water tank to make sure water level lower maximum level
Note: There might be other malfunctions, please contact service central for help if problem not
fixed.
Specifications
Name Humidifier Model H-580
Rated voltage 220V~ Rated frequency 50Hz
Rated power 25W(90W when heating) Capacity 3.5L
最大出雾量 Max mist 250mL/h
产品标准:Product standards
电气原理图 Electrical schematic
电源板 Power PCBA
雾化片 Atomizing plate
雾化板 Atomizing PCBA
控制板 Control PCBA
风扇 fan
干簧管 Reed switch
(Electrical schematic for reference only)
环保清单 不翻

用户保修卡 Warranty
Customer Name Model
Phone Product serial NO.
Date Purchase site
Address
Repair rules:
一, During the warranty period, the product is free of charge for one year repair if humidifier
under normal use (from the date of purchase, the sales certificate shall prevail)
二, Please kindly noted we will charge if there is one of below situations even during warranty
period
1, Damage cause by improper use, maintenance or storage by customer
2, Disassemble damage caused by unauthorized people
3, No warranty card or purchase proof
4, Actual model do not match warranty card model or model on warranty card altered
5, The appearance is naturally stained by the use.
6,Damage caused when humidifier for business purpose
7, Damage caused by force majeure
三, 不适用,不翻译
四, Please keep the warranty card in hand for warranty as we will not
provide replacement warranty card
五, For products that are not covered by the warranty and exceed the shelf
life, we will still serve you only charge the cost of parts or materials.