6 49-60763 Rev. 4
Temperature Control
USING THE FREEZER: Temperature Control
This electronic temperature control is located on the
front of the freezer door. The temperature is factory-
preset to provide satisfactory food storage temperatures.
To adjust the temperature setting, press - to decrease
WHPSHUDWXUHVDQGWRLQFUHDVHWHPSHUDWXUHV$OORZ
several hours for the temperature to stabilize between
adjustments.
High Temp Alarm
This electronic control has a high temperature alarm
feature. An alarm will sound if the freezer temperature
is high. To silence the alarm, press Alarm Reset on the
control panel.
The High Temp will continue to be displayed on the
control panel until set temperature has been restored.
The alarm will sound again if the temperature is not
restored and remains high in six hours.
Turbo Freeze
To enable Turbo Freeze, press Turbo Freeze until
7XUER)UHH]HON light turns on. The unit will be in
³7XUER)UHH]H´PRGHIRUKRXUVDQGWKHON light for
7XUER)UHH]HZLOOVWD\LOOXPLQDWHG$IWHUWKHKRXUVLV
completed, Turbo Freeze turns off automatically. The
ON light will be off to show that Turbo Freeze is off. To
exit Turbo FreezeEHIRUHWKHKRXUDXWRPDWLFVKXWRII
SUHVV7XUER)UHH]HXQWLOONOLJKWIRU7XUER)UHH]HLVRII
Control Lock
To lock the controls, press Control Lock and hold for 3
seconds until the ON light for Control Lock turns on.
To unlock, press and hold Control Lock for 3 seconds.
The ON light for Control Lock turns off and the control
panel will be unlocked. Control setting cannot be
changed when the control is locked.
Power Fail
If a power outage has caused the internal temperature
to be high, the high temp alarm will sound and the
temperature display will flash. Pressing Alarm Reset on
the control will silence the alarm and stop the flashing,
but High Temp/('ZLOOVWD\RQXQWLO\RXUIUHH]HU
reaches a safe storage temperature.
If the internal temperature has been restored before you
press Alarm Reset, the sound alarm will stop on its own,
DQGWKH+LJK7HPS/('ZLOOJRRIIDXWRPDWLFDOO\7KH
temperature display will continuing flashing to remind
you that a power outage has occurred. Press Alarm
Reset to stop the flashing.
Door Open Alarm
If your door has been left open for more than 2 minutes,
the control panel will display Door Open and will sound
DQDODUPXQWLOWKHGRRUKDVEHHQFORVHGRU'RRU2SHQ
is pressed on the control panel. If Door Open has been
pressed but the door has not been closed, Door Open
will continue to be displayed on the control panel until
the door has been closed. If 10 minutes after Door
Open has been pressed, the door is still open, the door
open alarm will sound again.
C or F Setting
7RFKDQJHEHWZHHQ&RU)SUHVVDQGKROGWKHDQG
pads at the same time for 3 seconds.
Control Dormant
The control settings are displayed at normal condition.
Press and hold Control Lock and Turbo Freeze for
VHFRQGV7KHHOHFWULFFRQWUROZLOOHQWHULQWR'RUPDQW
Mode and will not show the control settings. The control
settings will be displayed for 30 seconds if one of the
buttons on the control is pressed or the door is opened
ZKLOHLQ'RUPDQW0RGH3UHVVDQGKROGControl Lock
and Turbo Freeze for 3 seconds again will disable
'RUPDQW0RGH
°F
°C
Demo
ON
ON
High Temp
Door open
Hold 3 Sec
Turbo Freeze
Control Lock
Alarm Reset
High Temp Light
'RRU2SHQ/LJKW
Alarm Reset
Pad
7XUER)UHH]H/LJKW
Lock Controls Light
Increase Pad
'HFUHDVH3DG