The solenoid valve b can be found at
the front of the appliance. It has a 3/4"
connection thread (the position of the
solenoid valve as shown in the picture
may differ from your appliance).
The connection parts included with the
appliance permit the connection of
various water lines (a water line is not
included in delivery).
^ Remove the cap a from the solenoid
valve b.
^ Insert the adapter c into the union
nut d.
,
In the following, please note:
inserting the water filter incorrectly
can cause damage!
^ Place the water filter e on top of the
adapter c as shown in the picture.
,
Do not over-tighten the union
nut, damage can result!
^ Connect the union nut d to the
solenoid valve b and tighten it.
^ If you want to divert the water line by
90°, screw on the elbow f.
^ Vent the air from the water line by
opening the water supply
temporarily.
In case of a water line with a 1/4"
thread:
^ Connect the water line g (e.g.,
copper) using the clamping ring h
and the nut i on the adapter c or
elbow f.
In case of a water line with a 7/16"
24-UNS thread:
^ Connect the water line g directly to
the adapter c or elbow f (a
clamping ring h and nut i are not
required).
^ Slowly open the water shut-off valve
and check for leaks.