Installation
Check code Meaning Solution
9C1 Abnormal voltage detected.
Check the power connection. (Refer
to the “Connect the electrical wiring
(for electric models)” section)
If the problem continues, contact a
service center.
Exhaust ducting guide
Ducting
1. Make sure the dryer is installed properly so the air exhausts freely.
2. Use 4-inch rigid metal ducts. Tape all joints including the dryer connection. Never use
lint-trapping screws.
3. To facilitate the exhaust, keep the ducts as straight as possible.
Cleaning
Clean all old ducts before installing the dryer, and make sure the vent ap opens and
closes freely. We recommend that you clean the exhaust system annually or on a regular
basis.
WARNING
To prevent re, do not use plastic, thin-foil, or non-metal exible ducts of any kind.
Do not use a poor exhaust system because it slows down the dryer’s performance.
Do not use excessively long ducts that have multiple elbows.
Do not use crushed or clogged venting or ducts.