ELECTRIC DRYER ELECTRICAL CONNECTIONS
F
F
Direct Wire Connection
Remove Terminal Block Cover
Remove hold-down screw and terminal block cover.
Direct Wire Strain Relief
1. Insert strain relief.
Unscrew the removable conduit connector (A) and any screws
froma3/4"(19mm)ULListedstrainrelief.Putthethreaded
section of the strain relief (C) through the hole below the terminal
block opening (B). Reaching inside the terminal block opening,
screw the removable conduit connector (A) onto the strain
relief threads.
Put direct wire cable through the strain relief. The strain relief
shouldhaveatighttwiththedryercabinetandbeina
horizontal position. Tighten strain relief screw against the direct
wire cable.
2. Insert conduit into strain relief and tighten clamp.
A
B
C
3. Connect remaining wires under outer terminal block screws (F).
Tighten screws. Finally, reinstall terminal block cover to dryer
rear panel. Secure cover with hold-down screw. Now go to
“Venting Requirements.”
Connecting 3-Wire Connection: Power Supply Cord (cont.)
Fire Hazard
Use 10 gauge copper wire.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal.
Ground wire (green or bare wire) must be connected
to green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, re, or
electrical shock.