Loading ...
Loading ...
Loading ...
Page:
17
Page:
16
User Manual: User Manual:
Cleaning & Maintenance
CLEANING AND CARE
WARNING!
Before you begin maintenance, please unplug the machine and close the tap.
CLEANING THE CABINET
Proper maintenance on the washing machine can extend its working life. The surface can be cleaned
with diluted non-abrasive neutral detergents when necessary. If there is any water overow, use the
wet cloth to wipe it o immediately. No sharp items are allowed.
NOTE!
Formic acid and its diluted solvents or equivalent are forbidden, such as alcohol, solvents or
chemical products, etc.
CLEANING THE INLET FILTER
NOTE!
Inlet lter must be cleaned if there is less water.
Washing the lter in washing machine:
1. Screw o the inlet pipe from the rear of the machine.
2. Pull out the lter with long pliers and reinstall it back after being washed.
3. Use a brush to clean the lter.
4. Reconnect the inlet pipe.
Lint lter clean:
1. There is a built-in lint lter in your washer. It can help to collect lint during
washing cycle.
2. It is suggested to clean the lint lter every 10 cycles.
3. Take it out and clean the lter with water. Then place it back into the washer.
Magic lter
Normal lter
CLEANING THE DRAIN PUMP FILTER
WARNING!
Be careful of the hot water!
Allow detergent solution to cool down.
Unplug the machine to avoid electrical shock before washing.
Drain pump lter can lter the yarns and small foreign matters from the washing.
Clean the lter periodically to ensure the normal operation of washing machine.
CAUTION!
Make sure that valve cap and emergency drain hose are reinstalled properly, cap plates should be
inserted aligning to hole plates otherwise water may leak;
Some machines don’t have emergency drain hose, so step 2 and step 3 can be skipped.
Rotate lower cover cap directly to make water run into basin.
When the appliance is in use and depending on the program selected there can be hot water in
the pump. Never remove the pump cover during a wash cycle, always wait until the appliance has
nished the cycle, and is empty. When replacing the cover, ensure it is securely re-tightened.
Drain the water out
of the pump, using a
container to collect
Clean the lter
Open the lter by turning
to the counter clockwise
Restore it and adjust the
convex place to align at the
pump hole
Remove foreign objects
Tighten the pump
cover clockwise
Loading ...
Loading ...