SPECIFICATIONS
Read Before
Using
10
UNITS TFJ30PF TFJ30PR TFJ28PF TFJ28PR TFJ25PR TPJ24PF TPJ24PR/BR TFJ22PR TFJ20JR
USEFUL TOTAL (L) 806 806 764 764 686 630 630 588 531
VOLUME FREEZER (L) 301 301 284 284 243 229 229 175 175
FRESH FOOD (L) 505 505 480 480 443 401 401 413 356
ELECTRICAL VOLTAGE (V) SINGLE PHASE 100/100
POWER FREQUENCY (Hz) 50/60
SOURCE MOTORS (W) 247/238 247/238 247/238 247/238 252/245 248/233 248/233 243/231 241/228
HEATERS (W) 675/675 675/675 675/675 675/675 675/675 675/675 675/675 595/595 595/595
AVG MONTHLY ELECTRICAL 86/89 81/81 81/80 71/73 77/78
CONSUMPTION (KWH/MON)
COOLING METHOD AND COLD AIR CIRCULATION TYPE (INDIRECT COOLING)
FREEZER CODE
CONDENSER COOLING FORCED AIR (FAN COOLED CONDENSER)
DEFROST CONTROL AUTO START - AUTO STOP
DEFROST WATER REMOVAL FORCED AIR EVAPORATION
AUTOMATIC ICEMAKER YES
MOBILITY WHEELS ATTACHED
BUILT-IN POSSIBLE
DOOR REVERSIBILITY -
ELECTRICAL RATING (A) 15
WEIGHT (Kg) 168 168 163 163 143 159 159 132 123
CORD LENGTH (M) 2.2
* Values for useful internal volume and the Electrical Standard Values are based on the Japanese Industry Standard
(JIS C9607).
* Values separated by “/” indicate 50 Hz on left and 60 Hz on right. Others indicate common 50 Hz
and 60 Hz.
Freezer Performance
This freezer/refrigerator is “Four Star” coded.
Performance of freezer is classified by codes.
Each code indicates the performance capability according to the regulation
delineated in the Japanese Industry Standard (JIS C9607). The regulation
defines the test conditions for measuring the freezing-load temperature
(food temperature). The following table shows the test results:
CODE FREEZING-LOAD TEMP. FROZEN FOOD PRESERVATION
(FOOD TEMPERATURE) ESTIMATED TIME
Below -6°C. Approx. 1 week
Below -12°C. Approx. 1 month
or Below -18°C. Approx. 3 months