Loading ...
Loading ...
Loading ...
Alert Reason Solution
Keypad lashes red three
times with three beeps*.
One incorrect code entered. Re-enter code.
No user code programmed. Program at least one user code.
Programming timeout after ive
seconds.
Attempt programming procedure again.
Unsuccessful programming.
Keypad lashes red 15 times
with 15 beeps*
Three incorrect codes entered
within one minute.
Re-enter code after 60 second keypad
lockout.
Keypad lashes red with fast
beeping sound for three to
four seconds.
Low battery. Replace batteries.
Keypad lashes green with
continuous beeping sound
for two seconds.
Door jammed while attempting
to lock.
Manually re-lock door. If needed,
reposition strike.
*Beeping sound will only be heard if switch #3 is on.
4 / 4
© 2015 Spectrum Brands, Inc.
If no button is pressed for ive seconds, the system will time out, and
you will need to restart the procedure.
1 Keep door open.
Press Program
button once.
5 Re-enter user code. 6 Press Lock
button once.
If unsuccessful
Make sure to enter
the same valid code
in steps 3 and 5.
Test code
While the door is
open, test the user
code to make sure
it no longer unlocks
the door.
2 Press Lock
button once.
4 Press Lock
button once.
3 Enter user code
to be deleted.
SmartCode at a Glance
Deleting a single user code
Note: All codes may be deleted at once if the mastercode is enabled. For more information about the
mastercode, consult the online Programming and Troubleshooting Guide.
Reference Guide
Exterior
Back
panel
Program
button
Status
LED
Switches
Turnpiece
shaft
Note: When the cover is removed,
the turnpiece shaft can be used to
manually lock and unlock the door.
Interior (cover removed)
Switches and Status LED colors Troubleshooting
Switch Function
1
Door lock status LED blinks every 6
seconds
2
Lock automatically re-locks door 30
seconds after unlocking. Disabled if no
codes are programmed.
3 Audio
4 Not used.
Color Lock Status
Blinking green Unlocked
Blinking amber Locked
Blinking red Low battery
Solid red
Door handing process
did not work properly.
See the online
Programing and
Troubleshooting Guide.
1 2 3 4
On
Switches
Status
LED
O
System Alerts
Factory Reset
A factory reset will delete all codes associated with the lock.
Status
LED
1 Remove
battery pack.
2 Press and HOLD the Program
button while reinserting
the battery pack.
Keep holding the button for 30
seconds until the lock beeps
and the status LED lashes red.
Keypad
Lock
button
Keyway
SmartKey
tool hole
3 Press the Program button
once more. In 20 seconds,
when the LED lashes green
and you hear one beep, the
lock has been reset.
4 Perform the door handing process again
to teach the lock the orientation of the
door and add user codes to your lock.
A complete Programming and Troubleshooting Guide is
available on the SmartCode 913 page at www.kwikset.com.
1. Read all instructions in their entirety.
2. Familiarize yourself with all warning and caution statements.
3. Remind all family members of safety precautions.
4. Protect your user codes and mastercode.
5. Dispose of used batteries according to local laws and regulations.
CAUTION: Prevent unauthorized entry. Since anyone with access to the back panel
can change the user codes, you must restrict access to the back panel and routinely
check the user codes to ensure they have not been altered without your knowledge.
The use of a mastercode can help protect your system’s settings.
WARNING: This Manufacturer advises that no lock can provide complete security
by itself. This lock may be defeated by forcible or technical means, or evaded by
entry elsewhere on the property. No lock can substitute for caution, awareness of
your environment, and common sense. Builders hardware is available in multiple
performance grades to suit the application. In order to enhance security and reduce
risk, you should consult a qualiied locksmith or other security professional.
Important Safeguards