For WHG955SB. Also, The document are for others Westinghouse models: CHG642SB, CHG642WB, CHG646SB, CHG646WB, CHG606SB, CHG956SB, CHG956WB, SHG646SB, SHG956SB, ZHG645SA, ZHG955SA, WHG640SB, WHG640WB, WHG640SC, WHG640WC, WHG643SA, WHG643SB, WHG645SA, WHG645WA, WHG645SB, WHG645WB, WHG951SB, WHG953SB, WHG955SA, WHG955WA, WHG955WB

Loading ...
Loading ...
Loading ...
installation
Checking the gas supply
1.
Check the manometer zero point is correct.
2.
Connect the manometer to the cooktop pressure point. This
is located on the regulator.
3.
Turn on the gas supply and electricity and try to ignite
the gas.
tips & information
It will take additional time to light the gas for the first time as
air needs to be purged from the pipes.
4.
With the appliance operating check the outlet pressure:
when all burners of the appliance are operating
at maximum,
when the smallest burner of the appliance
is operating at minimum.
Under these conditions the outlet pressure should not vary
from the nominal outlet pressure of 1.00kPa by more than
+/0.20kPa.
If the regulator appears to not be performing satisfactorily,
then check the following points.
1.
If the outlet pressure is consistently too low then the inlet
pressure may be too low and adjustment of an upstream
regulator may be needed, or an upstream regulator or
valve with insufficient flow capacity may be present in the
gas supply line. If this is suspected then it may be necessary
to repeat the checks whilst
measuring both the inlet and outlet pressure to determine
if the inlet pressure is in the range 1.13 5kPa.
2.
Check that the regulator has been fitted to the gas supply
line in the correct orientation, the arrow on the base of the
body indicates the direction of gas flow.
Once these checks have been completed, if the regulator
still fails to perform in a satisfactory manner it should be
replaced.
Table 3
BURNER TYPE
NATURAL GAS
(Nominal test point pressure: 1.00kPa)
LPG
(Nominal test point pressure: 2.60kPa)
Injector size (mm)
Gas consumption
(MJ/h)
Injector size (mm)
Gas consumption
(MJ/h)
Small burner
1.00
5.1
0.55
4.0
Medium burner
1.35
9.0
0.70
6.5
Large burner
1.60
12.1
0.90
10.7
Wok burner
1.75
14.4
1.00
13.0
Gas Cooktops LP CONVERSION - DONGYANG 13