www.insigniaproducts.com
21
NS-RTM10BK0/NS-RTM10WH0/NS-RTM10SS0
Specifications
The refrigerator makes unusual
noises or vibrations.
The following sounds are normal:
Compressor running noises.
Air movement noise from the small fan motor in the freezer compartment or
other compartments.
Popping noise during automatic defrosting.
Clicking noise before the compressor starts.
Other unusual noises or vibrations may occur:
If you have items on the top of your refrigerator. Remove the items.
If your refrigerator is not level. See Leveling your refrigerator on page 9.
If your refrigerator is touching walls. Move it away from the walls.
If the shelves or drawers are installed incorrectly.
The outside of the refrigerator is
hot.
Heat dissipation from the condenser may make the outside feel hot. This is normal and
happens if:
The room temperature is high.
You have too much food in your refrigerator.
You open and close the doors excessively.
Water condenses on the outside
of the refrigerator.
Condensation on the exterior surface and door seal is normal when the room
humidity is high.
When you open the door, warm, moist outside air meets the cold dry air inside
your refrigerator. This is normal.
External dimensions
(H × W× D)
59.8 × 23.4 × 26.4 in. (152 × 59.5 × 67.1 cm)
Internal dimensions
(H × W× D)
Refrigerator compartment (H × W × D): 33.7 × 20 × 21.5 in. (85.6 × 50.5 x 54.5 cm)
Freezer compartment (H × W × D): 15.7 × 17.5 × 17.3 in. (40 × 44.5 × 44 cm)
Refrigerator shelf (W × D): 18.1 × 12.7 in. (46 × 32.3 cm)
Freezer shelf (W × D): 19.6 × 14.4 in. (49.7 × 36.7 cm)
Crisper (H × W × D): 7.9 × 17.8 × 12 in. (20 × 45.2 × 30.5 cm)
Depth with open door at 90°: 48.3 in. (122.6 cm)
Weight
Gross Weight: 127.9 lbs (58 kg)
Net Weight: 116.8 lbs (53 kg)
Temperature ranges Refrigerator: 32°F to 46°F (0°C to 8°C)
Freezer: -11°F to 10°F (-24°C to -12°C)
Power requirements AC115V~60Hz
Current 0.91A
Defrosting power 180W
Power cord length 6 ft. (1.8 m)
Power consumption per year 300 kwh
Certifications UL and Energy Star approved