en Operating the appliance
8
Switching over the indicator for circulating-air mode
For circulating-air mode, the electronic control must be
switched over accordingly:
The extractor hood must be connected and switched
off.
Touch and hold the # and x symbols at the same
time, until the " indicator lights up for circulating-
air mode "Starter Set". Repeatedly pressing and
holding this button combination causes the "
indicator to light up for the "CleanAir" circulating-air
module.
Repeatedly pressing and holding this button
combination switches the electronic control back
over to ducted operation (! indicator).
Audible signal
Switching on the audible signal
When the fan is switched off, press and hold the # and
+ symbols simultaneously for approximately three
seconds. An audible signal sounds as an
acknowledgement.
Switching off the audible signal
Repeat the "Switching on the audible signal" process.
Control panel model 2
Setting the fan
Switching on
Pull out the filter pull-out and touch the # symbol.
The fan will start at setting ƒ.
Slide your finger across the settings range ||| to
alter the fan speed.
Note: When the filter pull-out is pushed in, only fan
settings , ƒ and can be selected.
Switching off
Touch the # symbol. Slide in the filter pull-out.
Intensive setting
You can use the intensive setting if there is a large
build-up of odours and fumes/vapours.
Slide your finger to the right across the III settings
range. Intensive settings 2 and ƒ2 can be selected.
After approximately six minutes, the electronics
automatically reduce the fan to a lower setting . If you
want to end the intensive setting before the preset time
expires, slide your finger to the left across the III
settings range until the required fan setting is reached.
Boost function
The boost function is a short-term maximum power
setting which can be activated at any fan setting.
Touch the & symbol. After approximately 20 seconds,
the fan switches back to the previously set fan setting.
Fan run-on time
If you slide in the filter pull-out, the run-on time will be
activated for as long as the extractor hood is operating.
After approx. 10 minutes, the fan switches off
automatically.
Automatic mode
Switching on
Touch the # symbol.
The fan starts at setting ƒ.
Touch the ! symbol.
The optimum fan setting , ƒ or is automatically
set via a sensor.
Switching off
Touch the ! or # symbol to switch automatic mode
off.
The fan switches off automatically if the sensor no
longer detects a change in the air quality of the room.
Automatic mode can run for a maximum of 4 hours.
LQW
DXWR
Explanation
#
Fan on/off
=
Light on/off/dimming
&
Boost function (short-term maximum power)
!
Automatic mode with fan run-on
-|||+ Range of fan settings