Maintenance
Maintenance
Pump lter
It is advisable to clean the pump lter 5 or 6 times a year to prevent its clogging. A clogged
pump lter may reduce the bubble effect.
1. Turn off the washing machine, and
unplug the power cord.
2. Drain the remaining water inside the
drum drum. See the “Emergency drain”
section.
3. Gently press the top area of the lte
cover to open.
4. Turn the pump lter knob to the left, and
drain off the remaining water.
5. Clean the pump lter using soft brushes.
Make sure the drain pump propeller
inside the lter is unclogged.
6. Reinsert the pump lter, and turn the
lter knob to the right.
NOTE
• Some pump lters feature a safety knob
that is designed to prevent accidents
by children. To open the safety knob
of the pump lter, push in and turn it
anticlockwise. The spring mechanism of
the safety knob helps open the lter.
• To close the safety knob of the pump
lter, turn it clockwise. The spring makes
a rattling sound, which is normal.
NOTE
If the pump lter is clogged, an information code of “5C” appears on the screen.
CAUTION
• Make sure the lter knob is closed properly after cleaning the lter. Otherwise, this may
cause a leak.
• Make sure the lter is inserted properly after cleaning it. Otherwise, this may cause an
operational failure or a leak.